Device-Specific Conformal Reliability under Scanner-Level Acquisition Shift in Breast Ultrasound CAD.

Ismail Hakki Kinalioglu

Department of Actuarial Sciences, Selcuk Universitesi Fen Fakultesi, Selcuk University, Faculty of Science, Konya, Konya, 42130, Turkey.

Key points

From the paper's conclusion
  • These results document scanner-level differences in empirical conformal reliability and motivate evaluating target recalibration when an independent target-domain reliability audit provides evidence of undercoverage, rather than establishing a prospective trigger rule.

Abstract

Conformal prediction provides finite-sample coverage control under exchangeability, but empirical reliability may change across scanner-defined deployment domains. We audit three conformal procedures and one non-conformal abstention baseline on leave-one-device-out (LODO) partitions of BUS-BRA using EfficientNet-B0, ResNet-50 and ConvNeXt-Tiny. All conformal thresholds are computed by direct finite-sample order-statistic indexing. The primary prediction and score unit is the image; source splits are patient-disjoint, target calibration/test partitions are patient-disjoint within each recalibration draw, and patient-cluster bootstrap plus patient-aggregated analyses assess within-patient dependence. At nominal α=0.05, EfficientNet-B0 Mondrian CP gives malignant set-miss rates of 0.004 for GE Logiq 7, 0.002 for GE Logiq 5 and 0.244 for Toshiba; the Toshiba patient-cluster 95% interval is 0.140-0.359. Patient aggregation preserves the contrast (0.194 for Toshiba versus 0.000 for both GE devices). In paired target recalibration, k=10 lowers Toshiba mean miss rate from 0.246 to 0.057 while increasing abstention to 0.603, whereas the same intervention raises the GE means to 0.060 and 0.067. Across the 500 Toshiba k=10 seed-draw combinations, the post-recalibration median miss rate is 0.021 (IQR 0.000-0.063), and 96.4% of draws improve relative to their paired pre-recalibration value. A finite-resolution analysis shows that α=0.02 is rank-unavailable for all tested few-shot conditions; under direct finite-sample order-statistic indexing, α=0.02 and α=0.05 coincide at k=5 and k=10 because both select the observed class maxima, but they separate in the larger k=20 condition. These results document scanner-level differences in empirical conformal reliability and motivate evaluating target recalibration when an independent target-domain reliability audit provides evidence of undercoverage, rather than establishing a prospective trigger rule.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers