Image-Enhanced Autonomous Navigation in Intestinal Robotics: A Threshold-Triggered Approach Combining Dark-Area Localization and Morphological Contour GuidanceShort title: Enhancing Visibility and Navigation Precision in Confined Spaces.
Shiwei Wang, Junying Yuan, Haoran Deng, Hanyu Deng, Xiuquan Yue, Tianshi Zhang, Shenjin Chen, Haishan Chen
Ningbo University, No. 818 Fenghua Road, Jiangbei District, Ningbo City, Zhejiang Province, Ningbo, Zhejiang, 315211, China. · Nanfang College Guangzhou, No. 882, Wenquan Avenue, Conghua District, Guangzhou, Guangzhou, Guangdong, 510970, China.
Key points
From the paper's conclusion- We propose a threshold-triggered, vision-driven framework incorporating Navier-Stokes-based highlight suppression.
Abstract
Robotic endoscopy offers a potential route to autonomous gastrointestinal navigation. However, autonomous intestinal navigation is hindered by non-rigid lumen deformation and visual degradation from specular reflections, which compromise accurate perception and stable control. We propose a threshold-triggered, vision-driven framework incorporating Navier-Stokes-based highlight suppression. Algorithmically, the system is governed by a threshold-triggered mechanism that acts as a conditional perception gate, dynamically alternating between a lightweight "dark-area guidance" algorithm for approximately centered navigation and a more detailed "contour-based guidance" pipeline for corrective steering. The switching policy avoids executing highlight suppression and morphological contour processing in every frame. In phantom-based trials, the system achieved an average speed of 3.10 cm/s on the triangular path. Highlight suppression increased the proportion of frames with normalized center error below 0.1 from 65% to 71%, below 0.2 from 95% to 97%, and below 0.3 from 98% to 100%. The adaptive mechanism decreased runtime by approximately 2% compared to continuous contour processing. Although this absolute reduction was modest, it recovered approximately 89% of the runtime difference between the contour-only and dark-area-only baselines. These phantom-based results support conditional perception allocation while keeping average processing time close to that of lightweight navigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ColoACT: Multi-Cue Action Chunking for Smooth Autonomous Colon Navigation on a Self-Propelled Endoscopic RobotarXiv · 2026
- A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control FrameworkarXiv · 2026
- Image brightness indicates lumen direction in a patient-derived virtual colon: a learning-free approach to semi-autonomous colonoscopymedRxiv · 2026
- Multimodal Progress-Residual Fusion for Anticipating Navigation Retreat in Robotic Flexible EndoscopyarXiv · 2026
- Exploring RGBD Models for Force Estimation in Surgical Manipulation of Small IntestineCurrent Directions in Biomedical Engineering · 2026
- Adaptive Deep Video Frame Interpolation for Robust Laparoscopic Visualization: A Comparative EvaluationInternational Journal of Imaging Systems and Technology · 2026