Effect of column geometry and shear links on punching shear behaviour of flat slabs
Akinpelu M.A., Sanni R.O., Gabriel D.S., Salman A.M., Raheem I.A
Key points
From the paper's conclusion- Notably, the slab supported on the cruciform column recorded the highest unreinforced punching shear capacity of 542.17 kN, while the slab supported on the L-shaped column reached the maximum capacity of 730.9 kN with 50 mm shear reinforcement spacing—an increase of 47% over its unreinforced state.
Abstract
This study investigates the combined effects of column geometry and shear reinforcement on the punching shear behavior of reinforced concrete (RC) flat slabs using nonlinear finite element analysis (FEA). A three-dimensional finite element model was developed in ABAQUS, calibrated against experimental data, and extended to a parametric study of twelve slabs to examine the influence of four column geometries—square, L-shaped, T-shaped, and cruciform—under varying shear reinforcement spacings (50 mm and 100 mm). The Concrete Damaged Plasticity Model (CDPM) was employed to simulate cracking, stiffness degradation, and ultimate failure mechanisms. Results reveal that irregular column geometries amplify stress concentrations and crack propagation, yet they enhance punching shear capacity compared to regular geometries, the inclusion of shear reinforcement substantially improved load-bearing capacity and ductility. Notably, the slab supported on the cruciform column recorded the highest unreinforced punching shear capacity of 542.17 kN, while the slab supported on the L-shaped column reached the maximum capacity of 730.9 kN with 50 mm shear reinforcement spacing—an increase of 47% over its unreinforced state. Code comparisons indicate that ACI 318-19 provided the closest predictions to FEA results, whereas Eurocode 2 and Model Code 2010 exhibited conservative results, particularly for irregular columns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Strengthening of punching shear of flat slab–column connections through hybrid near‐surface mounted and externally bonded systems: Experimental, numerical, and analytical studyStructural Concrete · 2026
- Punching Shear Capacity Model in Reinforced Concrete Flat Slab Without Shear Reinforcement, Based on Fracture Mechanics and Statistical ApproachEngineering Reports · 2026
- Comparative evaluation of finite element direct design and equivalent frame methods for reinforced concrete flat slabs with and without drop panels under Eurocode 2Discover Applied Sciences · 2026
- Comprehensive Finite Element Assessment of Seismic Performance in Steel Panel Zone Connections for Cruciform Columns Using Curved Plate GeometriesBuildings · 2026
- Assessment of unbalanced moment resistance in corner slab–column joints in RC infrastructure using Finite Element AnalysisIOP Conference Series: Earth and Environmental Science · 2026
- Code-based refinement and finite element validation of punching shear design for reinforced concrete footings.Scientific reports · 2026