  • Hence, this study experimentally investigates the tensile pullout test of a single screw anchor installed at two different embedment depths, i.e., 40 mm and 70 mm, in thin SFRC panels with 100 mm thickness.

Abstract

As the construction industry advances toward net-zero carbon emissions, steel fibre-reinforced concrete (SFRC) can be adopted to enable thinner structural members in buildings and tunnel applications, such as hollow-core slabs, modular building walls, and tunnel linings. Screw anchors are widely used in concrete connections and are classified as post-installed mechanical anchors in the current anchor design standard for normal concrete. The anchor embedment depth-to-concrete thickness requirements are often limited by current codes and anchor manufacturers’ specifications. Hence, this study experimentally investigates the tensile pullout test of a single screw anchor installed at two different embedment depths, i.e., 40 mm and 70 mm, in thin SFRC panels with 100 mm thickness. The ultimate load capacities of the screw anchors with the corresponding failure modes are presented. The results showed that post-peak softening will occur when anchors are installed in SFRC. In addition, adding steel fibres to concrete changes the failure behaviour of the screw anchor as compared with normal concrete.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers