IOP Conference Series: Earth and Environmental Science

Crack Behaviour of basalt fabric-reinforced cementitious composites with varying textile ratio and mortar type

T.N.S. Bhagyasri, Dr. D. Ravi Prasad

Key points

From the paper's conclusion
  • These findings demonstrate the potential of hybrid fiber-reinforced cementitious composite for structural rehabilitation and retrofitting applications.

Abstract

To overcome the limitations of organic adhesives in structural strengthening, textile-reinforced cementitious composite (TRC) or fabric-reinforced cementitious mortar (FRCM) has emerged as a promising alternative to traditional fibre-reinforced polymers (FRPs). However, TRCs still face challenges, including the brittleness of the cementitious matrix and yarn slippage in the mid-plane, which affect the overall performance of the composite. This study examines an approach to addressing these issues by incorporating short, discrete fibers into the matrix as secondary reinforcement to enhance ductility and textile utilization. An experimental program was conducted to investigate the effects of mortar composition and textile reinforcement ratio on the cracking behaviour of basalt fabric-reinforced composites (BFRCMs) using bi-directional fabrics under direct tension. Three mortar types were developed: CM0 (cementitious mortar without fibers), CM10 (mortar with 10% ultrafine slag), and CMH (mortar reinforced with 0.5 vol% hybrid fibers). Each composite was reinforced with one, two, and three textile layers to vary the textile reinforcement ratio. Experimental results revealed that the inclusion of short fibers significantly improved crack distribution, leading to finer and more numerous cracks. Increasing the textile ratio reduced average crack width and spacing, indicating improved stress transfer efficiency. Among composites, the hybrid fiber-reinforced composite (CMH) outperformed non-fibrous variants due to improved textile–matrix interaction. The combination of hybrid fibers and three textile layers (B3 CMH) exhibited the best crack control, with crack width reduced to 0.09 mm, corresponding to reductions of 70.97 % and 59.09 % compared to B3 CM0 and B3 CM10 respectively, while direct tensile strength increased to 9.32 MPa and improved by 66.73 %, 50.32 % compared to B3CM0, B3CM10 respectively, highlighting the synergistic benefits of fiber hybridization in FRCM. These findings demonstrate the potential of hybrid fiber-reinforced cementitious composite for structural rehabilitation and retrofitting applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers