IOP Conference Series: Earth and Environmental Science

Reliability and safety integrity level (SIL) evaluation framework for unattended machinery spaces (UMS) on tankers

Akbar Antoni, Dwi Priyanta, Trika Pitana

Key points

From the paper's conclusion
  • This study proposes an integrated data-driven framework for assessing the reliability and functional safety of tanker UMS systems using operational alarm data, Fuzzy Failure Mode and Effects Analysis (Fuzzy FMEA), Bayesian Belief Networks (BBN), Probability of Failure on Demand average (PFD avg ), and SIL assessment in accordance with IEC 61508.

Abstract

Unattended Machinery Space (UMS) systems have become an essential component of modern tanker operations, enabling engine room monitoring and control without continuous engine-room attendance. As reliance on automation increases, ensuring the reliability and functional safety of UMS systems becomes increasingly important. Although large volumes of operational alarm data are continuously generated, these data are rarely utilized as quantitative evidence for reliability and Safety Integrity Level (SIL) evaluation. This study proposes an integrated data-driven framework for assessing the reliability and functional safety of tanker UMS systems using operational alarm data, Fuzzy Failure Mode and Effects Analysis (Fuzzy FMEA), Bayesian Belief Networks (BBN), Probability of Failure on Demand average (PFD avg ), and SIL assessment in accordance with IEC 61508. Historical alarm records collected from actual tanker operations were analysed to identify critical failure patterns and subsystem vulnerabilities. Fuzzy FMEA was applied to prioritize failure modes under uncertainty, while BBN was used to model probabilistic dependencies and estimate posterior failure probabilities based on alarm evidence. These probabilities were subsequently transformed into PFD avg values for SIL determination. The results indicate that the Main Engine/Propulsion, Fuel System, and Electrical/Generator System represent the dominant contributors to alarm occurrence and operational risk. Bayesian inference showed a significant increase in posterior failure probabilities after alarm evidence was incorporated. The estimated PFD avg values ranged from 2.438 × 10 −3 to 3.288 × 10 −3 , corresponding to SIL 2 according to IEC 61508 low-demand mode criteria. The proposed framework demonstrates how operational alarm evidence can be systematically transformed into quantitative reliability and functional safety indicators, providing a practical decision-support tool for reliability management, maintenance prioritization, and safety verification in tanker UMS operations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Reliability and safety integrity level (SIL) evaluation framework for unattended machinery spaces (UMS) on tankers — Science Skim