DC cryogenic modeling of open-source SkyWater 130 nm MOSFETs at 77 K using BSIM4
F. Beall, A. Rimal, O. Seidel, Y. Mei, A.D. McDonald, I. Parmaksiz, V.A. Chirayath, J. Asaadi,
Key points
From the paper's conclusion- We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K.
Abstract
Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130 nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS). However, our models had a systematic overprediction specifically for the measured pMOS devices at the lowest measured drain bias. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate CMOS device models at 77 K.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surrogate-Assisted Compact-Model Extraction for SKY130 CMOS at 77 KarXiv · 2026
- CryoModel-4K: physics-based BSIM4 extension for 28 nm bulk CMOS compact modeling at 4 KelvinScientific Reports · 2026
- A cryogenic characterization platform for commercial off-the-shelf (COTS) electronic devices in liquid xenon detectors for high-energy physics experiments.The Review of scientific instruments · 2026
- Investigation on Hot-Carrier Injection Mechanisms and Reliability Design-Based Strategies in Cryogenically Operated CMOS ROICs for Infrared Focal Plane Arrays.Sensors (Basel, Switzerland) · 2026
- Cryogenic Recharacterization of a Commercial 22 nm FD-SOI Foundry Standard-Cell LibraryarXiv · 2026
- Cryogenic performance of Silicon Photo-Multipliers at LN$_2$ temperature and at 3 K in the RES-NOVA cryostatarXiv · 2026