Journal of Instrumentation

Performance evaluation of a D-band (130–170 GHz) heterodyne receiver front-end for radiometric applications

Varsha Siju, Yash Dasadia, Ajay Kumar

Key points

From the paper's conclusion
  • This work presents the characterization methodology and performance evaluation of a commercially available D-band heterodyne receiver front-end operating over the 130–170 GHz frequency range.

Abstract

The performance of a millimeter-wave radiometer is strongly influenced by the characteristics of its radio-frequency (RF) front-end, making comprehensive experimental characterization essential prior to system deployment. This work presents the characterization methodology and performance evaluation of a commercially available D-band heterodyne receiver front-end operating over the 130–170 GHz frequency range. The study investigates the performance of the principal passive and active microwave components, including IMPATT local oscillators, balanced mixers, high-pass filters, cavity band-pass filters, isolators, directional couplers, and the calibration noise source, followed by evaluation of the integrated receiver front-end and its interface with an 8-channel intermediate-frequency (IF) receiver covering 1–20 GHz. The 130 GHz and 150 GHz IMPATT oscillators were characterized in terms of output power, phase noise, frequency stability, and short-term frequency drift. The balanced mixers exhibited an average conversion loss of approximately 9 dB while providing down-conversion from the 130–170 GHz RF band to a 1–20 GHz IF. Passive microwave components were evaluated through measurements of insertion loss, isolation, coupling characteristics, and transmission response, while a calibrated noise source with manufacturer-specified excess noise ratio (ENR) values was used as part of the receiver characterisation procedure.The complete receiver chain was subsequently validated through RF-to-IF measurements using an 8-channel IF receiver. The experimental results establish the performance of the individual receiver components as well as the integrated front-end architecture, demonstrating its suitability for high-sensitivity millimeter-wave radiometry and electron cyclotron emission diagnostic applications. The characterization methodology presented in this work also provides a practical framework for the evaluation and integration of D-band heterodyne receiver systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers