Cherenkov-light imaging of beta-particles emitted from lead-212 (Pb-212) and decayed products using high sensitivity CCD camera
Seiichi Yamamoto, Masao Yoshino, Kazuaki Tsukada, Hidetoshi Kikunaga, Takuya Yokokita, Kenji Shirasaki, Kohei Nakanishi, Kei Kamada,
Key points
From the paper's conclusion- In conclusion, Cherenkov-light imaging of Pb-212 and decayed products provides high spatial resolution and shows potential for applications requiring precise distribution measurement of Pb-212 and its decayed products.
Abstract
Lead-212 (Pb-212) is a promising alpha emitter for radionuclide therapy due to its remarkable clinical efficacy in treating cancer as well as generator-based delivery of the radionuclides. The Pb-212 and decayed products emit beta particles with energies exceeding the Cherenkov-light threshold, making it possible to image them by detecting Cherenkov light. However, the performance of Cherenkov-light imaging for Pb-212 and decayed products has not been assessed through experiments or simulations. To address this, we evaluated the performance of Cherenkov-light imaging for Pb-212 and the decayed products using both phantom experiments and simulations. A solution of Pb-212 and its decayed products was placed in an acrylic rod phantom, and Cherenkov-light images were acquired using a high-sensitivity CCD camera. We obtained clear image of Cherenkov-light and the resulting images demonstrated a spatial resolution of ∼0.5 mm full width at half maximum (FWHM). Monte Carlo simulations indicated that the theoretical spatial resolution of Cherenkov light emitted from Pb-212 and decayed products was ∼0.1 mm FWHM, finer than the experimental results, suggesting blurring the experimental image. Based on the simulation, the Cherenkov light was primarily attributed to beta particles emitted from Bi-212, with additional contributions from beta particles emitted by Tl-208. In conclusion, Cherenkov-light imaging of Pb-212 and decayed products provides high spatial resolution and shows potential for applications requiring precise distribution measurement of Pb-212 and its decayed products.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy-resolved imaging ofαparticles emitted by the decay products of Pb-212 using a YAP(Ce)-based imaging detector for targeted radionuclide therapy.Biomedical physics & engineering express · 2026
- Lead radionuclides for theranostic applications in nuclear medicine: from atom to bedsideTheranostics · 2025
- Advances in Dosimetry and Imaging for 203Pb and 212Pb RadiotheranosticsSeminars in Nuclear Medicine · 2025
- Preclinical 203/212 Pb-DOTA–Based Pretargeted Radioimmunotherapy in Nude Mice Bearing Established Human Colorectal Cancer XenograftsJournal of Nuclear Medicine · 2026
- In vivo Quantitative Tomography of 225Ac Daughters in a Prostate Cancer Mouse Model with a Compton CamerabioRxiv · 2026
- Assessing the feasibility of quantitative SPECT imaging for low 212Pb activity concentrations using anthropomorphic phantomsEJNMMI Physics · 2026