Development and performance validation of a coaxial time-of-flight mass spectrometer based on microchip-laser ablation

Wenbo Liu, Huan Wang, Yang Cao, Peng Sang, Yaning Liu, Baoquan Li

Key points

From the paper's conclusion
  • These results indicate that the developed microchip-laser-ablation coaxial TOF mass spectrometer can provide rapid mass-spectral responses for typical metallic and natural rock samples, offering an experimental basis for the subsequent miniaturization and engineering development of payloads for in situ compositional analysis of solid samples in space missions.

Abstract

To meet the requirements for in situ compositional analysis of solid samples in lunar, Martian, and asteroid exploration missions, a prototype coaxial time-of-flight mass spectrometer (TOF-MS) based on microchip-laser ablation was developed in this study, and its performance was validated using metallic and rock samples. The system employs a microchip pulsed laser with a wavelength of 1064 nm, a pulse width of 500 ps, and a single-pulse energy of 16.8 μJ as the ablation source. An optical coupling system and an ultrafast photoelectric triggering system were developed accordingly. In combination with a coaxial ion extraction structure, an Einzel lens, a field-free drift tube, a two-stage ion reflectron, and a coaxial apertured microchannel plate (MCP) detector, the instrument enables time-of-flight analysis of ions generated by laser ablation of solid samples. The overall dimensions of the instrument are 150 mm × 122 mm × 224 mm. Ion-optical simulation results show that the optimized Einzel lens and two-stage reflector effectively constrain the initial angular divergence of ions and enable ion-beam shaping, energy compensation, and flight-path folding within a compact configuration, yielding a simulated mass resolving power of approximately 726 and an overall simulated ion-transmission efficiency of 15.5%. Experimental results demonstrate that characteristic metallic ion peaks, including Al + + and Al 2 + from aluminum samples and 63 Cu + , 65 Cu + , 63 Cu 2+ and 65 Cu 2+ from copper samples, can be obtained. In single-shot mass spectra of natural rock samples, peaks associated with light elements, alkali metals, and aluminosilicate-related elements can also be detected, indicating that the system is capable of rapidly identifying major rock-forming elements in complex geological samples. Peak-width analysis shows that the mass resolution of single-shot spectra is on the order of 10 2 , while that of accumulated spectra can reach approximately 55. These results indicate that the developed microchip-laser-ablation coaxial TOF mass spectrometer can provide rapid mass-spectral responses for typical metallic and natural rock samples, offering an experimental basis for the subsequent miniaturization and engineering development of payloads for in situ compositional analysis of solid samples in space missions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development and performance validation of a coaxial time-of-flight mass spectrometer based on microchip-laser ablation — Science Skim