Advances in supercritical CO 2 cycles for next-generation CSP plants: Insights from the TOPCSP project
Vladimir Naumov, Gioele Di Marcoberardino, Paolo Iora
Key points
From the paper's conclusion- Within the TOPCSP project, advanced supercritical CO 2 (sCO 2 ) and CO 2 mixture power cycles have been investigated to improve the performance and competitiveness of next generation concentrating solar power (CSP) plants.
Abstract
Within the TOPCSP project, advanced supercritical CO 2 (sCO 2 ) and CO 2 mixture power cycles have been investigated to improve the performance and competitiveness of next generation concentrating solar power (CSP) plants. Since conventional sCO 2 cycles are highly sensitive to ambient temperature, working fluids based on CO 2 mixtures (CO 2 with small amounts of high-critical-temperature dopants) were evaluated to enable transcritical operation at higher minimum cycle temperatures. Thermohydraulic and mechanical designs of shell and tube primary and recuperative heat exchangers were developed for both sCO 2 and CO 2 mixture cycles, followed by the experimental investigation using water to model molten salt. In addition, primary and recuperative heat exchangers, condensers, coolers, and turbines were sized for steam Rankine, sCO 2 , and CO 2 -mixture power cycles to evaluate component mass, cost and flexibility. A review of candidate dopants considering thermodynamic, environmental, and safety criteria was done. A techno-economic CSP plant model was developed and validated. Preliminary analyses indicated levelized cost of electricity (LCOE) reductions for GeCl 4 and Cl 3 FSi based mixtures. However, thermal stability tests revealed insufficient stability of GeCl 4 and C 3 F 6 , leading to the selection of SiCl 4 as the most promising dopant. The CO 2 +SiCl 4 mixture demonstrated superior techno-economic performance compared with conventional sCO 2 cycles at turbine inlet temperatures of 550–700°C and showed potential competitiveness with steam Rankine cycles. Off-design analyses of recuperated cycles, including detailed recuperator and cooler/condenser models, identified an optimal design air temperature of 35°C and a cooler approach temperature of 5°C for Seville, Spain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Analysis of Recompression and Tri-Compression S-CO2 Brayton Cycles for Solar Power Tower Systems: Thermodynamics, Exergy, and Techno-EconomicsEnergies · 2026
- Guiding the optimization of the thermal-hydraulic performance of advanced-CSP (concentrating solar power) systems integrated with thermal energy storage, considering the pseudo-boiling phenomenonEnergy · 2026
- Progresses in Potential Spectrally Selective Absorbing Coatings for Ultra-High-Temperature (≥600 °C) Solar Thermal GenerationACS Applied Energy Materials · 2026
- Influences of the Key Parameters on the Supercritical CO2 Cycle Performance in Combined Cycle Power PlantEnergies · 2026
- Supercritical CO2 Flow and Heat Transfer in Compact Thermal Systems: A Critical Review of Mechanisms, Geometries, and Enhancement StrategiesEnergies · 2026
- Exergetic-cost analysis of pumped thermal energy storage (PTES) systems using s-CO2 mixtures as a working fluidJournal of Energy Storage · 2025