Numerical study of the cooling effect in solid-state hydrogen storage via adsorption
Costantino Barbieri, Michele Stefanizzi, Sergio M. Camporeale, Marco Torresi
Key points
From the paper's conclusion- The results show that the lower temperatures significantly increase the storage capacity due to the enhanced hydrogen adsorption.
Abstract
Increasing hydrogen storage capacity and safety are some of the main issues for an effective energy transition toward net zero CO 2 emissions. Although there are fairly well-established methods such as compressed gas and liquid storage, both have significant disadvantages in terms of safety and energy costs. Storing hydrogen in gaseous form means to achieve pressures ranging from 200 to 900 bar, which would limit the size of the tanks and could put safety at risk. Storing hydrogen in liquid form, on the other hand, means operating at cryogenic temperatures, down to the hydrogen liquefaction point of 20 K; in this case, the specific energy costs of maintaining the liquefied state would be very high (about 35% of the lower calorific value of hydrogen). This paper aims to highlight the new frontier of hydrogen storage: solid-state storage and in particular, cryo-adsorption. In this context, hydrogen is physically and reversibly bound within a porous matrix. The aim of this storage method is to mitigate the limitations of compressed and liquid hydrogen storage, in order to facilitate the introduction of hydrogen into a more competitive energy market. This work numerically analyzes solid-phase hydrogen storage via adsorption under cryogenic conditions. Using CFD simulations, the loading and dormancy phases of a tank filled with AX-21 activated carbon were investigated, evaluating the influence of external temperature. The parametric analysis was conducted to estimate the performance of the system for three different external wall temperatures (100 K, 150 K, and 200 K), aiming to achieve a target pressure of 100 bar inside the tank at the end of the charging phase. The results show that the lower temperatures significantly increase the storage capacity due to the enhanced hydrogen adsorption. Indeed, when the outer wall temperature is set to 100 K, the total mass of hydrogen stored (m tot = 58 g) is approximately twice that recorded when the outer wall temperature is set to 200 K (m tot = 31 g). The study also highlights the utilization rate of the porous matrix and the importance of investigating thermal gradients in order to improve it. The utilization rate reaches satisfactory levels (82% when T w = 200 K at the end of charge) when there is a uniform temperature gradient in the tank.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Recent Advances in Solid-State Hydrogen Storage Based on Metal Hydrides and Nanoporous Carbon Materials.Nanomaterials (Basel, Switzerland) · 2026
- Understanding factors affecting storage capacity and reproducibility in realistic ambient-temperature hydrogen physisorptionSustainable Energy & Fuels · 2026
- Performance Analysis of an Adsorption-Based CO2 Reservoir for Compressed CO2 Energy Storage: Experiments and Dynamic ModelingChemEngineering · 2026
- Review of hydrogen storage using AB, AB2, HEA, and solid solution metal hydridesInternational Journal of Hydrogen Energy · 2026
- A critical review of cushion gas in underground hydrogen storage: Thermophysical properties, interfacial interactions, and numerical perspectivesAdvances in Colloid and Interface Science · 2025
- Interfacial dynamics and mass transfer in underground hydrogen storage applications: A review of H₂ flow, stability and storage performanceADVANCES IN GEO-ENERGY RESEARCH · 2025