Thermal Characterisation of a Cryogenic Storage System within a Simulated Ship Hull Structure: Numerical and Experimental Investigation under Vacuum Insulation Degradation
Ronelly José De Souza, Marco Russo Cirillo, Marco Bogar, Emiliano Costa, Salvatore Manuel Renda, Benedetto Di Paolo, Stefano Valeri, Marco La Valle,
Key points
From the paper's conclusion- The results show that the loss of vacuum fundamentally modifies the thermal field: the radial temperature difference across the chamber increases from approximately 2 °C to 7 °C, and a marked buoyancy-driven vertical stratification develops, with temperature gradients on the tank surface reaching nearly 12 °C.
Abstract
The thermal management of cryogenic storage systems is a key challenge for the safe and efficient use of liquefied energy carriers such as liquid hydrogen (LH 2 ). Understanding the heat transfer mechanisms governing boil-off generation and their sensitivity to the cryogenic tank insulation quality is essential for the design and optimisation of these systems. This paper presents a combined numerical and experimental investigation of the thermal behaviour of a laboratory-scale cryogenic storage system under two different vacuum insulation conditions of the cryogenic tank. A dedicated test bench was developed, consisting of a 100 L liquid-nitrogen Dewar tank enclosed within a custom-built test chamber composed of two concentric aluminium boxes, creating confined air gaps that reproduce the thermal resistances encountered between a cryogenic tank and its surroundings. The setup was instrumented with a network of 92 thermocouples distributed across five radial positions and three vertical levels, enabling a spatially determined characterisation of the temperature distribution. Two experimental campaigns were conducted: one under the manufacturer’s design vacuum level (5x10 −6 mbar) and a second under a degraded insulation scenario corresponding to a vacuum-loss event (150 mbar). The results show that the loss of vacuum fundamentally modifies the thermal field: the radial temperature difference across the chamber increases from approximately 2 °C to 7 °C, and a marked buoyancy-driven vertical stratification develops, with temperature gradients on the tank surface reaching nearly 12 °C. A three-dimensional CFD model was developed and validated against the measurements, achieving a maximum relative error below 3.5 % across all monitoring points and both conditions. The validated methodology is applicable to the assessment of LH 2 storage configurations, where accurate prediction of heat ingress is critical for boil-off management and safe operation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mobility-Oriented Multiphysics, Insulation and Evidence Frameworks for Liquid Hydrogen Storage TanksJournal of Ocean Engineering and Technology · 2026
- CFD Model Predictions of Zero Boil‑Off Unvented and Vented Tank Filling in MicrogravityMicrogravity Science and Technology · 2026
- Dynamic Modelling of Cryogenic Liquid Hydrogen Tanks for Hydrogen-Powered Aircraft Fuel SystemsJournal of Physics: Conference Series · 2026
- Predictive Simulation of Thermal Stratification and Transient Boil-Off from Cryogenic Liquids Using “Shortcut” ConvectionEnergies · 2026
- Tracking cryogenic tank failure from inception to critical warming: a site-specific analysis of sample-storage risk.Journal of assisted reproduction and genetics · 2026