  • The results of this study will provide valuable insights into the flexibility and efficiency of LHTES systems under different HTF heating and cooling rate conditions.

Abstract

Latent Heat Thermal Energy Storage (LHTES) systems are widely adopted in renewable energy applications due to their ability to address the discrepancy between energy supply and demand. In recent years, the charge and discharge cycles of these systems have been analysed in depth under standardised Heat Transfer Fluid (HTF) inlet conditions. However, due to the inherently fluctuating nature of renewable energy plants, the HTF is subject to variable thermal inputs. Specifically, Concentrated Solar Power (CSP) plants are characterised by fluctuations due to changing weather conditions and seasonal variations in solar radiation. This phenomenon causes different heating rates and maximum temperatures reached by the HTF at the LHTES inlet. This study experimentally investigates the impact of HTF heating and cooling rates on the temporal response of a single-tube LHTES for high-temperature applications. The test rig uses Solar Salt (a 40/60 wt% mixture of NaNO 3 / KNO 3 ) as Phase Change Material (PCM) and diathermic oil as HTF. The experimental campaign focuses on simulating the variable thermal inputs typical of CSP plants. By replicating these dynamic profiles, the research aims to characterise the heat transfer performance and the PCM behaviour during realistic charging and discharging cycles. The investigation evaluates three distinct operating scenarios with varying HTF heating and cooling rates, each comprising three cycles performed between fixed temperature boundaries to ensure data repeatability. The high degree of consistency observed in the maximum temperatures reached by the PCM is indicative of its short-term operational stability and the reliability of the storage process under dynamic transients. The results of this study will provide valuable insights into the flexibility and efficiency of LHTES systems under different HTF heating and cooling rate conditions. This will contribute to the optimisation of solar-integrated thermal storage solutions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers