Mesoscale-microscale wind coupling for accurate building energy performance predictions in urban environments
Camilla Lops, Nicola Germano, Matteo Falone, Mariano Pierantozzi, Paolo Zazzini
Key points
From the paper's conclusion- These findings confirm that high-fidelity wind boundary conditions improve the reliability of urban building energy assessments and demonstrate the generality and transferability of the proposed framework across different geographic and climatic contexts.
Abstract
The increasing complexity of urban microclimates, driven by ongoing urbanization and climate change, poses significant challenges to the reliable prediction of building energy performance. Standard meteorological files commonly adopted in dynamic energy simulations fail to capture the spatial heterogeneity of local wind fields, leading to potentially large errors in both heating and cooling demand estimates. This work proposes a multiscale wind-analysis framework that couples mesoscale atmospheric simulations with microscale Computational Fluid Dynamics (CFD) analyses to generate physically consistent, high-resolution wind boundary conditions for building energy assessment. At the mesoscale level, the Fifth-Generation Penn State/NCAR Mesoscale Model (MM5) is applied over a suburban site in Pescara, Central Italy, testing multiple physical parameterization schemes. The resulting wind fields are then down-scaled through a set of CFD simulations, covering the four main incoming wind directions and solving the wind flow within the urban canopy. The coupled wind data are subsequently used as boundary conditions for dynamic energy simulations of a real case-study building. Comparing pre- and post-coupling results reveals significant differences in predicted annual energy demands: heating loads decrease by approximately 8% across all MM5 configurations, reflecting locally reduced wind intensities, while cooling loads increase by 37-56% depending on the adopted parameterization scheme, owing to the sheltering effect of surrounding buildings on natural ventilation. These findings confirm that high-fidelity wind boundary conditions improve the reliability of urban building energy assessments and demonstrate the generality and transferability of the proposed framework across different geographic and climatic contexts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Conditional Flow Matching for Generation of 3D Multi-variable Instantaneous Urban Microclimate FieldsarXiv · 2026
- Coupling urban microclimate and building energy modelling: An open-source parametric workflowBuilding Simulation · 2026
- FluidUrban v1.0: enhancing urban ventilation and pollutant dispersion modelling with three-dimensional dynamic adaptive meshes optimisationGeoscientific Model Development · 2026
- Fourier neural operator for real-time simulation of 3D dynamic urban microclimatearXiv · 2026
- Calibration of urban building energy model using smart meter data for district peak load predictionApplied Energy · 2026
- Enhancing geometric fidelity and wind-field prediction accuracy in complex urban environments using a Cartesian cut-cell CFD modelSustainable Cities and Society · 2026