Journal of Physics: Conference Series

Modeling Biomethane-Fed Molten Carbonate Fuel Cells (MCFCs) in Aspen Plus ® for Combined Heat and Power (CHP)

Benedicta Croce, Kumail Abdi, Francesca Mennilli, Mosè Rossi, Gabriele Comodi

Key points

From the paper's conclusion
  • Hence, demonstrating the potential of biomethane-fueled MCFC systems for efficient CHP operation.

Abstract

The transition towards low-carbon energy systems requires flexible renewable fuels suitable for efficient electricity and heat generation. Biomethane is a promising energy carrier because it can be used in high-temperature fuel cells, internal combustion engines, or injected into the natural gas grid for distributed energy applications. Molten Carbonate Fuel Cells (MCFCs) are particularly attractive for Combined Heat and Power (CHP) systems due to their high operating temperature, which enables internal reforming and recovery of high-grade thermal energy. This work develops a steady-state Aspen Plus ® model of a biomethane-fueled MCFC system for CHP applications. The model combines internal Steam Methane Reforming (SMR) and Water Gas Shift (WGS) reactions, described through Langmuir Hinshelwood Hougen Watson (LHHW) kinetic expressions, with a reduced-order electrochemical MCFC model implemented using calculator routines. The biomethane feed rate was set to 150 Nm 3 /h, while the anode operating temperature was fixed at 650°C. Model validation was carried out by comparing simulated and experimental polarization curves over a current density range of 0.001–0.040 A/cm 2 . The Aspen Plus ® model reproduced the experimental trend with absolute voltage deviations between 0.01 and 0.035 V, confirming the dominance of ohmic losses in the investigated range. The influence of the Steam-to-carbon (S/C) ratio was also evaluated for values of 2.0, 2.5, 3.0, and 3.5. The results showed that the S/C ratio had a limited effect on the polarisation behaviour. Finally, the integrated afterburner and heat recovery network allowed approximately 382 kW th is available to meet various thermal demands. The total electrical power output of the system, provided by the fuel cell stack, is 687.6 kW e providing electrical efficiency of approximately 46%, resulting in an overall cogeneration efficiency of 71.5%. Hence, demonstrating the potential of biomethane-fueled MCFC systems for efficient CHP operation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Modeling Biomethane-Fed Molten Carbonate Fuel Cells (MCFCs) in Aspen Plus ® for Combined Heat and Power (CHP) — Science Skim