Transient Thermal and Electrical Performance of a Hybrid PV–TEG System with Hysteresis-Controlled Intermittent Water Cooling under Simulated Solar Irradiation

S Wahyu, S Afnan, P Suharmanto, T Sujadi, A F Ritonga

Key points

From the paper's conclusion
  • These findings demonstrate that hysteresis-controlled intermittent water cooling provides an effective thermal regulation approach for improving transient electrical output stability in small-scale hybrid PV–TEG systems.

Abstract

Photovoltaic (PV) modules experience electrical performance degradation under elevated operating temperatures because a considerable fraction of incident solar radiation is converted into heat rather than electricity. Integrating thermoelectric generators (TEGs) with PV modules offers an opportunity to utilize part of this thermal energy; however, the coupled PV–TEG system requires appropriate thermal management because PV and TEG components have different thermal requirements. This study experimentally investigates the transient thermal and electrical performance of a small-scale hybrid PV–TEG system equipped with hysteresis-controlled intermittent front-surface water cooling under simulated solar irradiation. Two PV–TEG configurations were evaluated: an uncooled reference system and a temperature-controlled water-cooled system. The cooling strategy employed a hysteresis temperature band, where water spraying was activated at 40 °C and stopped at 35 °C. Electrical and thermal parameters were monitored every 2 min during a 120 min experimental period. The uncooled and cooled configurations received average irradiance levels of 653.99 W/m 2 and 593.32 W/m 2 , respectively. The hysteresis-controlled cooling system reduced the average PV surface temperature from 43.71 °C to 36.53 °C and limited the maximum temperature to 40.19 °C through four intermittent cooling cycles. Under the actual experimental conditions, the cooled configuration produced an average electrical output power of 0.12282 W compared with 0.10289 W for the uncooled system. After irradiance normalization using a constant-resistance-load-based correction model, the estimated output power increased to 0.13537 W, corresponding to a 31.57% improvement compared with the uncooled configuration. These findings demonstrate that hysteresis-controlled intermittent water cooling provides an effective thermal regulation approach for improving transient electrical output stability in small-scale hybrid PV–TEG systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers