Development and Thermal Validation of a Portable Guarded Hot Box for Steady-State Window U-Value Measurements
Karisma Rahmawati, Dian Permata Lestari, Nurcahya Pradana Taufik Prakisya, Maqbul Kamaruddin, Dewanto Harjunowibowo
Key points
From the paper's conclusion- The findings demonstrate that minimising heat losses is essential for accurate U-value determination in compact portable GHB systems intended for field applications.
Abstract
Guarded Hot-box (GHB) has become popular for measuring the thermal transmittance of materials to investigate building energy efficiency. However, previous studies show that developing a portable apparatus and achieving a fast steady-state is difficult. Therefore, this study presents the design, calibration, and validation of a low-cost portable guarded hot box (GHB) for in-situ measurement of the U-value of building materials. We used two identical cubic chambers equipped with thermoelectric modules, PID temperature controllers, thermocouples, and a heat flux sensor. A 5 mm single-pane glass specimen with an area of 0.01 m 2 was evaluated under two wall-chamber configurations (uninsulated and aerogel-insulated). We calibrated the thermocouple before testing to improve sensor consistency. The experimental results showed that the uninsulated chamber produced an apparent U-value of 4.07 ± 0.04 W/m 2 K. This underestimated the reference range due to uncontrolled heat losses through the chamber walls. After applying a 3 mm aerogel insulation layer, the measured U-value increased to 5.95 ± 0.04 W/m 2 K, which is close to published reference values for standard single glass. In terms of energy efficiency, the insulated configuration could reduce average power consumption by 51.25%, indicating that improved thermal stability and energy efficiency of the apparatus were achieved. The findings demonstrate that minimising heat losses is essential for accurate U-value determination in compact portable GHB systems intended for field applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty-aware determination of thermal transmittance and systematic evaluation of insulation retrofit scenarios for energy-efficient building envelopeJournal of Thermal Analysis and Calorimetry · 2026
- Addressing uncertainty in U-value estimation with infrared thermography: A Kriging-based model calibration approachEnergy and Buildings · 2025
- Optimizing Window Installation Depths to Reduce Thermal Bridging in Hot-Climate Building EnvelopesBuildings · 2026
- Commercial low-emissivity glass-based transparent heater for effective defogging in glazed window refrigeratorProceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering · 2026
- UAV-Based Infrared Thermography for Qualitative and Quantitative Building Energy Assessment: A ReviewEnergies · 2026
- A field framework for U-values and dynamic response in prefabricated rural dwellings: theory–measurement gaps and ranking reversalEnergy and Buildings · 2026