  • The results show that as cavitation intensifies, the peak frequency of the water noise shifts from high to low, with a significant increase in noise energy in the mid- and low-frequency bands.

Abstract

The fixed cone valve is prone to cavitation under conditions of high pressure differential and small opening, which causes abnormal vibrations and noise in the valve body, thereby shortening its service life. In this study, water noise at different cavitation numbers was measured experimentally for a fixed cone valve with a diameter of DN450 at 30% opening. A cavitation number-water noise curve was obtained to distinguish four flow stages, and the water noise spectra of different flow stages were analyzed. The changes in the cavitation-induced noise spectrum of the cone valve at different cavitation stages were identified. Additionally, the effect of air ingestion on the water noise spectrum during cavitating flow conditions was investigated. The results show that as cavitation intensifies, the peak frequency of the water noise shifts from high to low, with a significant increase in noise energy in the mid- and low-frequency bands. After air ingestion through the air injection pipe, the sound pressure levels of the noise in the mid- and low-frequency bands decrease significantly and exhibit a stronger regularity. This indicates that air ingestion into the cone valve can effectively reduce cavitation intensity inside the valve under high-pressure differential conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers