Journal of Physics: Conference Series

Research on inverse transient analysis of pipeline leak based on message passing interface and genetic algorithm

Xiaodong Jin, Xueling Tang, Xiaoqin Li

Computational

Key points

From the paper's conclusion
  • These results are not notably different from those obtained with ITA-GA, which produced a relative location error of 3.67% and a relative flow error of 15.50%.

Abstract

To address the issue of large computational demand and long computation time in numerical simulations of transient flows using the Inverse Transient Analysis Method (ITA), a pipeline leakage inversion model based on the message passing interface (MPI) and genetic algorithm (GA), termed ITA-MPI-GA, is proposed in this paper. Parallel acceleration of inverse transient analysis computations is achieved on a single multi-core computer. First, a forward transient analysis is performed using the method of characteristics (MOC), and a pipeline leakage forward model is established by incorporating MIAB friction. The fitting performance of this model is then validated. The results show that the numerical simulation values obtained from the model are in good agreement with the experimental data. On this basis, a GA-based pipeline leakage inversion model (ITA-GA) is constructed by introducing GA into the forward model. Furthermore, MPI parallel technology is employed to partition the core computational components of ITA-GA, including objective function evaluation and optimization iterations, across multiple processes. Data coordination and synchronization among processes are realized through the MPI communication mechanism, leading to the ITA-MPI-GA model. To evaluate the performance of the proposed model, a single-leakage case in a typical pipeline system is selected as a benchmark scenario, and leakage parameter inversion is performed using both ITA-GA and ITA-MPI-GA under identical hardware configurations and parameter settings. The results show that ITA-MPI-GA yields inversion parameters of 0.7293 for the relative leakage location and 0.1982 for the relative leakage flow rate, with corresponding relative errors of 2.76% and 15.91%, respectively. These results are not notably different from those obtained with ITA-GA, which produced a relative location error of 3.67% and a relative flow error of 15.50%. In terms of computational efficiency, ITA-GA required approximately 2700 seconds, whereas ITA-MPI-GA reduced the computation time to about 320 seconds. This demonstrates the feasibility and effectiveness of ITA-MPI-GA in improving computational efficiency.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers