Journal of Physics: Conference Series

Flow Field Analysis and Structural Optimization of an Integrated Cooling Fan for Outer Rotor Permanent Magnet Brushless DC Motors

Mengyu Qu, Shuwen Deng, Wanzhao Li, Jingxuan Wang, Quanwu Li, Bili Deng, Yuchuan Wang

Key points

From the paper's conclusion
  • The results indicate that the key objective of integrated cooling structure optimization is not simply to increase the overall mass flow rate, but to improve ventilation conditions in critical regions by regulating pressure distribution and airflow allocation.

Abstract

To address the problems of limited internal flow space, multi-region flow coupling, and insufficient ventilation in critical regions of outer-rotor permanent magnet brushless DC motors (OR-PMBLDCMs), an integrated forced-air cooling structure combining the cooling fan with the outer rotor housing is proposed in this study. The impeller is integrated into the end of the outer rotor and directly driven by rotor rotation to induce internal airflow. A hybrid ventilation configuration consisting of bottom axial air inlets, side radial air inlets, and radial air outlets is adopted to optimize the internal airflow organization without increasing the overall structural dimensions, thereby enhancing airflow transport capability in critical regions. A three-dimensional computational fluid dynamics (CFD) model is developed while maintaining the same fan outer diameter and overall motor dimensions. The model incorporates the rotating impeller, magnet gap, rotor–stator air gap, winding slot channels, and multi-inlet ventilation structure. Using the CFD method, a parametric investigation is conducted to evaluate the effects of blade height and number on the internal velocity and pressure fields, mass flow rate, and flow characteristics in critical regions. The results demonstrate that the impeller geometric parameters significantly regulate the internal airflow organization of the outer-rotor motor by modifying the airflow distribution among different flow passages and affecting the local velocity levels in critical regions. Within the investigated parameter range, the optimized configuration reduces system pressure loss and improves airflow transport in the magnet gap, air gap, and winding slot regions. Among these regions, the magnet gap exhibits the most significant response to structural variations. The results indicate that the key objective of integrated cooling structure optimization is not simply to increase the overall mass flow rate, but to improve ventilation conditions in critical regions by regulating pressure distribution and airflow allocation. This study provides a reference for the design of high-efficiency forced-air cooling structures for outer-rotor permanent magnet brushless DC motors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Flow Field Analysis and Structural Optimization of an Integrated Cooling Fan for Outer Rotor Permanent Magnet Brushless DC Motors — Science Skim