Effect of Volute Tongue Position on the Wide Operating Range Performance of a Centrifugal Fan with a Controlled-Vortex Volute
Junlong Wang, Wei Wang, Xingqi Luo, Jiameng Ren, Jinling Lu, Jianjun Feng
Key points
From the paper's conclusion- A reasonable volute tongue position can effectively suppress flow separation in the tongue region under high-flow operating conditions, weaken the large-scale vortex structures, and reduce their vortex scales, thereby decreasing the vortex losses in the volute and enhancing the efficient operating range of the fan.
Abstract
To improve the performance of a centrifugal fan under high-flow operating conditions and enhance its wide-operating-range efficiency, a parametric investigation of the volute tongue position is conducted based on a previously optimized controlled-vortex volute. The position of the volute tongue relative to the impeller is adjusted to change the minimum distance between the volute tongue and the impeller outlet. Full-channel numerical simulations are performed to reveal the effects of different volute tongue positions on the performance over the entire flow range, as well as on the flow structures and vortex characteristics in the tongue region. Results demonstrate that the volute tongue position has a significant influence on the performance of the centrifugal fan under high-flow operating conditions, whereas its effect at the design condition is relatively limited. At the normalized flow rate Q / Q des =1.31, where Q and Q des denote the actual and design flow rates, respectively, the optimal volute tongue scheme increases the efficiency by 1.88% and the total pressure rise by 2.17%, while maintaining the efficiency at the design condition nearly unchanged. Mechanistic analysis reveals that multi-scale vortex structures exist in the volute, mainly concentrated in the tongue region and biased toward the impeller front-shroud side. A reasonable volute tongue position can effectively suppress flow separation in the tongue region under high-flow operating conditions, weaken the large-scale vortex structures, and reduce their vortex scales, thereby decreasing the vortex losses in the volute and enhancing the efficient operating range of the fan. This study provides a theoretical reference for the energy-saving optimization and engineering retrofit of centrifugal fans under wide operating conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on the influence of split airfoil inlet guide vanes on aerodynamic performance of centrifugal fan under wide operating conditionsJournal of Physics: Conference Series · 2026
- Coupled Optimization and Mechanism Study of Collector and Impeller for a High-Pressure Centrifugal FanJournal of Physics: Conference Series · 2026
- Optimization of blade installation angle and internal flow of a non-volute centrifugal fan using the steepest descent methodAIP Advances · 2026
- Aerodynamic performance analysis and optimization of key parameters in a centrifugal compressorJournal of Physics: Conference Series · 2026
- Effect of tandem blade structure of centrifugal pumps on cavitation performanceJournal of Physics: Conference Series · 2026
- Research on improvement method for inter-blade vortex in Francis turbine based on CFDJournal of Physics: Conference Series · 2026