Journal of Physics: Conference Series

Research on Modal Characteristics of the Runner and Head Cover of a Variable-Speed Pump-Turbine for Pumped Storage

Tao Liu, Tengda Xu, Fei Ye, Huili Bi, Hongyu Chen, Xijie Song, Zan Zhou, Zhengwei Wang

Key points

From the paper's conclusion
  • The results show that the rotor–stator interaction excitation presents a 4-nodal-diameter pattern; the natural frequency of the runner’s 4-nodal-diameter mode is 207⌧Hz, with safety margins of 23.2%–41.7% relative to the dominant excitation frequency; the 4-nodal-diameter natural frequency of stationary components such as the head cover is 2531⌧Hz, with safety margins of 1741%–2016%; and within a±

Abstract

Against the backdrop of the “dual carbon” goals and the construction of a new-type power system, variable-speed pumped storage units have become a development focus due to their wide-range speed regulation and fast response. Taking the variable-speed pump-turbine of a pumped storage power station as the research object, this paper addresses the risks of hydraulic excitation and structural resonance. A three-dimensional fully coupled model including the runner, head cover, stay ring, bottom ring, and internal flow field is established using fluid–structure interaction and acoustic–structure coupling modal analysis methods. The characteristics of rotor–stator interaction excitation, the wet modes of the runner and stationary components, and the resonance safety under dual regulation of rotational speed and guide vane opening are analyzed. The results show that the rotor–stator interaction excitation presents a 4-nodal-diameter pattern; the natural frequency of the runner’s 4-nodal-diameter mode is 207⌧Hz, with safety margins of 23.2%–41.7% relative to the dominant excitation frequency; the 4-nodal-diameter natural frequency of stationary components such as the head cover is 2531⌧Hz, with safety margins of 1741%–2016%; and within a±7% speed variation range around the rated speed and the full range of guide vane openings, all structural modal frequencies avoid the hydraulic excitation frequencies, posing no resonance risk. The research results can provide a theoretical basis and technical support for the structural design, vibration suppression, and safe and stable operation of large variable-speed pumped storage units.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers