Effect of Tip Clearance on the Pressure Pulsation Characteristics of a Helico-Axial Gas–Liquid Multiphase Pump

XianMing Ma, Wei Han, YuLong Dong

Key points

From the paper's conclusion
  • To clarify the influence of tip clearance on pressure pulsation characteristics, a full-passage numerical investigation was carried out for a self-designed single-stage helico-axial multiphase pump.

Abstract

Tip clearance is an inherent structural gap in helico-axial gas-liquid multiphase pumps and is closely related to tip leakage flow, local vortex structures and unsteady pressure pulsation. To clarify the influence of tip clearance on pressure pulsation characteristics, a full-passage numerical investigation was carried out for a self-designed single-stage helico-axial multiphase pump. The Eulerian multiphase model and the SST k-ω turbulence model were adopted, and the numerical method was validated by grid independence, time-step independence and experimental hydraulic performance data. The design flow rate, head and rotational speed were 100 m 3 /h, 30 m and 4500 r/min, respectively. Under an inlet gas volume fraction of 30%, pressure monitoring points were arranged along the impeller tip-clearance region and in the near-shroud region of the diffuser. The pressure pulsation coefficient, root-mean-square pulsation intensity and peak-to-peak value were used to evaluate the time-domain response, while fast Fourier transform was used to identify dominant frequency components. The results show that the pressure pulsation in the impeller and diffuser regions exhibits clear periodicity and is mainly governed by impeller rotation and rotor-stator interaction. Along the flow direction, the pulsation intensity is relatively weak at the impeller inlet, becomes more sensitive in the middle and rear passages, and reaches a higher level near the impeller outlet. On the impeller outlet cross-section, the pulsation intensity follows the order suction side > clearance middle > pressure side. With increasing tip clearance, both the pulsation intensity and peak-to-peak value at the impeller outlet first increase and then decrease, reaching their maximum at a clearance of 1.0 mm. Frequency-domain results indicate that tip clearance mainly changes spectral amplitude rather than the dominant peak positions. The non-monotonic pressure pulsation response is attributed to the coupled action of tip leakage flow development, local pressure difference, gas accumulation, vortex evolution and non-uniform outlet flow. The results provide a reference for tip-clearance optimization and pressure pulsation suppression in helico-axial multiphase pumps.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effect of Tip Clearance on the Pressure Pulsation Characteristics of a Helico-Axial Gas–Liquid Multiphase Pump — Science Skim