Failure Analysis of Corrosion in the Shell-Side Outlet Pipe and Flange of the 125-E111 Water Heater
Cong Deng, Jiayue Liu, Huasheng Hu
Key points
From the paper's conclusion- In response to the abnormal corrosion-induced wall thinning observed in the shell-side outlet nozzle and flange of a 125-E111 water heater at a certain petrochemical company, this paper systematically investigates the causes of corrosion failure using methods such as macroscopic morphological observation, wall thickness measurement, chemical composition analysis, mechanical property testing, metal
Abstract
In response to the abnormal corrosion-induced wall thinning observed in the shell-side outlet nozzle and flange of a 125-E111 water heater at a certain petrochemical company, this paper systematically investigates the causes of corrosion failure using methods such as macroscopic morphological observation, wall thickness measurement, chemical composition analysis, mechanical property testing, metallographic characterization, and scanning electron microscopy (SEM)-energy dispersive spectroscopy (EDS) analysis. The results indicate that the chemical composition, mechanical properties, and microstructure of the failed nozzles and flanges all comply with the requirements of the corresponding material standards; the material itself was not the cause of corrosion. Corrosion damage was concentrated on the outer walls of the components, while the inner walls remained intact. The corrosion products consisted primarily of iron oxides, along with sulfides and chlorides, exhibiting typical characteristics of corrosion under insulation (CUI). Based on an analysis of the equipment’s operating environment, it is believed that installation defects or operational damage to the insulation layer allowed external moisture to penetrate. Under the combined action of corrosive agents such as chloride ions and sulfides in the coastal atmosphere, the interior of the insulation layer was subjected to a long-term electrochemical corrosion environment characterized by alternating wet and dry conditions, ultimately leading to localized corrosion and wall thinning of the tube. This paper clarifies the failure mode and formation mechanism and proposes targeted prevention and control measures, which can serve as a technical reference for corrosion safety management of similar petrochemical heat exchangers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Failure Analysis of Economizer Tube Leakage Caused by Localized Internal Corrosion at Weld-Root RegionsRecent in Engineering Science and Technology · 2026
- Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry.Materials (Basel, Switzerland) · 2026
- Theoretical and experimental investigation on the erosion-corrosion failure of an L245N steel elbow pipeline in a gas field produced water systemJournal of Materials Research and Technology · 2026
- Corrosion Failure Analysis of 316L Stainless Steel Exposed to the China's Bohai Sea Water‐Air Interfacial Environment for 2.5 yearsMaterials and Corrosion · 2026
- Analysis of Corrosion Failure of the Positioning Sleeve of a Limit PositionerCorrosion and Materials Degradation · 2026
- Corrosion–Fatigue Damage Characteristics and Evolution Mechanisms of Failed Sucker RodsProcesses · 2026