Journal of Physics: Conference Series

Treatment of cutting waste liquid and cleaning wastewater from metal processing by coagulation-tubular microfiltration and two-stage low-pressure evaporation

Xia Zhu, Ruozheng Li, Chong Zhao, Ying Tian, Liming Xing, Ming Zhang

Key points

From the paper's conclusion
  • An integrated process combining coagulation-tubular microfiltration (TMF) pretreatment and two-stage low-pressure evaporation was proposed for the co-treatment of cutting waste liquid and cleaning wastewater with a huge gap in COD concentrations.

Abstract

An integrated process combining coagulation-tubular microfiltration (TMF) pretreatment and two-stage low-pressure evaporation was proposed for the co-treatment of cutting waste liquid and cleaning wastewater with a huge gap in COD concentrations. Owing to the extremely high COD of cutting waste liquid, a staged treatment scheme was designed to split the organic load. Coagulation coupled with TMF pretreatment removed over 80% of COD contaminants. The first-stage low-pressure evaporation operated at 16 kPa generated clean condensate, which was mixed with cleaning wastewater and fed into the second evaporator. The combined two-stage treatment produced final condensate with a COD of 410 mg/L, complying with the Class III discharge limit (≤ 500 mg/L) specified in Tianjin’s Integrated Wastewater Discharge Standard (DB12/356-2018). Meanwhile, the overall water recovery rate reached 75%.

Read the paper