Journal of Physics: Conference Series

Calculation and analysis of electromagnetic vibration and foot response in PM motors

Biwen Chen, Zhenlai Ma, Haijun Feng, Wanbo Yu, Guoping Li, Bo Zhang, Yi Zhang

Key points

From the paper's conclusion
  • The dominant foot vibration peaks at 400 Hz (16th order).

Abstract

Variable-frequency drive (VFD) fed PMSMs are widely used in centrifugal pump units. To address electromagnetic vibration from supply harmonics, this study analyzes the JTYC180L-16 PMSM using a coupled electromagnetic-structural model. Analytical derivation of inverter harmonics and 2D/3D finite element analyses—accounting for lamination anisotropy and pre-stress—reveal the vibration characteristics. Results indicate that VFD switching harmonics couple with the main field, generating high-frequency force waves (3400–4600 Hz). The dominant foot vibration peaks at 400 Hz (16th order). The proposed method provides a theoretical basis and computational reference for low-vibration design in marine PMSMs

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers