Journal of Physics: Conference Series

Infrared thermography-based quantitative identification of micro-leakage in H 2 /O 2 gas generators

Yumin Tu, Yuanjun Zhang, Mengfei Zhang, Wuyi Li

Key points

From the paper's conclusion
  • The results indicate that dynamic infrared enhancement and confidence-weighted estimation provide a practical non-contact route for quantitative identification of weak H 2 /O 2 micro-leakage.

Abstract

H 2 /O 2 gas-generator micro-leakage produces weak and localized thermal signatures that are difficult to separate from infrared background radiation. This study presents an infrared thermography-based method for quantitative micro-leakage identification. A controllable H 2 /O 2 leakage test rig was used to acquire infrared temperature sequences over an engineering-relevant leakage range of 8-20 mg/s. A dynamic-reference-temperature mapping strategy was developed to convert temperature matrices into pseudo-color infrared images and enhance weak flame features under varying thermal backgrounds. The enhanced images were then used for leakage-region localization and leakage-flow classification. For quantitative estimation, classifier posterior probabilities were converted into continuous leakage-flow estimates using a Top-k confidence-weighted scheme. The weighted estimator reduced root mean square error (RMSE) and mean absolute error (MAE) to 1.47 mg/s and 1.10 mg/s, respectively, compared with 1.81 mg/s and 1.20 mg/s for the discrete Top-1 strategy. The results indicate that dynamic infrared enhancement and confidence-weighted estimation provide a practical non-contact route for quantitative identification of weak H 2 /O 2 micro-leakage.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers