Journal of Physics: Conference Series

Development status of the ESS cryogenic moderator system

Hideki Tatsumoto, Theodoros Vasilopoulos, Iris Haag

Key points

From the paper's conclusion
  • The ESS Cryogenic Moderator System (CMS) is designed to supply subcooled liquid hydrogen (18 K and 1.0 MPa) with a parahydrogen fraction exceeding 99.5% to the two hydrogen moderators, maintaining the temperature rise across the moderators within 3 K.

Abstract

The ESS Cryogenic Moderator System (CMS) is designed to supply subcooled liquid hydrogen (18 K and 1.0 MPa) with a parahydrogen fraction exceeding 99.5% to the two hydrogen moderators, maintaining the temperature rise across the moderators within 3 K. The CMS is cooled by the Target Moderator CryoPlant (TMCP), a large-scale 20-K helium refrigerator with a cooling power of 30.3 kW at 15 K. An ortho-to-parahydrogen catalyst is installed to ensure the required parahydrogen fraction, which is measured in situ using a newly developed Raman-spectroscopy-based system. The temperature distribution variations induced by proton beam injection or trip result in pressure Rluctuations. A buffer tank is used to mitigate these pressure Rluctuations, while the valve box in the TMCP compensates for dynamic heat load variations by regulating the feed helium Rlow rate without altering the TMCP cooling power. Preliminary commissioning was conducted using helium prior to hydrogen operation in 2024. The Rirst hydrogen cooldown of the CMS was successfully completed in March 2025. Performance tests are currently underway to optimize operating conditions and to establish appropriate operating procedures for the automated control system.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers