Journal of Physics: Conference Series

Design and Validation of a Thin Aluminium Lid for a new Solid Deuterium Moderator Vessel at the UCN facility at PSI

Dominic Schori, Bertrand Blau, Jörg Welte, Katharina Liefert, Bernhard Lauss, Geza Zsigmond

Key points

From the paper's conclusion
  • For the UCN facility at PSI a new design of the solid deuterium moderator vessel was developed within the frame of a major refurbishment project called ‘UCN EZE’.

Abstract

For the UCN facility at PSI a new design of the solid deuterium moderator vessel was developed within the frame of a major refurbishment project called ‘UCN EZE’. In addition to the design improvements of the cold moderator vessel, the project includes the replacement of the entire central insertion unit, which consists of several components, such as a central shutter, a new, highly polished vertical neutron guide, and a large cryopump. This publication will focus on the new moderator vessel, with particular emphasis on the newly developed aluminium lid.