Journal of Physics: Conference Series

Monte Carlo Investigation of SPNDs for the Monitoring of the Position of the ISIS Proton Beam

Katherina Gelborova, Steven Lilley, Lina Quintieri

Key points

From the paper's conclusion
  • With cobalt emitter SPNDs in a triangulation set-up for monitoring of the proton beam position, signals are found to vary by around 1 to 10% per centimetre of beam offset.

Abstract

The Goldstein Monte Carlo method is implemented in FLUKA to preliminarily assess the responses of self-powered neutron detectors (SPNDs) in the target reflector and moderator assembly (TRaM) of Target Station 1 (TS-1) at the ISIS Neutron and Muon Source. It is found that the prompt signal tends to be majority neutron-induced, and in the range of 0.1 nA to 100 mA, depending on the yet unknown time response of the system. With cobalt emitter SPNDs in a triangulation set-up for monitoring of the proton beam position, signals are found to vary by around 1 to 10% per centimetre of beam offset. The maximum SPND current variation due to proton beam width is estimated to likely be of a similar magnitude. Further investigation and development of methods is required to evaluate the signal-to-noise ratio of the prompt signal.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers