Journal of Physics: Conference Series

Application of SAMMY User-Defined Resolution Function at Spallation Neutron Sources

Lukas Zavorka, Luiz Leal, Erik B. Iverson, Jesse Brown, Kemal Ramić, Chris Chapman, Klaus Guber, Goran Arbanas,

Key points

From the paper's conclusion
  • This paper demonstrates the application of SAMMY user-defined resolution function (UDR) at spallation neutron sources.

Abstract

This paper demonstrates the application of SAMMY user-defined resolution function (UDR) at spallation neutron sources. SAMMY is a multilevel R-matrix fitting code for neutron data using Bayes’ equations. The resolution function describes the energy spread of neutrons at a time-of-flight detector, and it can be processed in SAMMY in two formats: analytical or UDR. Whereas the analytical function requires extensive parameter fitting, the UDR can be calculated accurately with a Monte Carlo radiation-transport code, such as MCNP6, using a detailed geometry model of the neutron source. With the UDR, SAMMY provides endless opportunities to advance the field of neutron science. We discuss three distinct applications in which the UDR has been found invaluable. The first application focuses on validating the neutron generation at a spallation source in the resonance energy region (1 eV to 1 MeV). The second application uses a well validated resolution function to determine the time distribution of the incident proton pulse, thus serving as an alternative proton beam time monitor. The last and increasingly important application focuses on advancing the non-destructive assay techniques, specifically the neutron resonance transmission analysis with modern neutron instruments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Application of SAMMY User-Defined Resolution Function at Spallation Neutron Sources — Science Skim