To identify true and false bump pressure near the theoretical bump position, a two-dimensional axisymmetric Abaqus/Explicit model was established. Casing outer-wall acceleration responses were extracted at multiple measuring points. The results show that both processes excite casing vibration, but true bump pressure presents a more continuous locking-type response, whereas false bump pressure shows intermittent segmented pulses. The waveform at P0 and the spatial distribution of peak resultant acceleration provide an auxiliary basis for bump-pressure identification.