Journal of Physics: Conference Series

Effect of bolt preload on contact pressure distribution and sliding distance in bolted connections

Runze Sun

Key points

From the paper's conclusion
  • The results indicate that the preload mainly strengthened the annular compression zone around the bolt hole, while the sliding response represented localized tangential compatibility deformation in the high-pressure contact region.

Abstract

Bolted connections are key load-transfer components in wind turbine flange structures, and their service performance is strongly affected by the bolt preload. To clarify the role of preload in local interface behavior, a simplified three-dimensional finite element model of a bolted flange segment was established. Four preload levels, 1 kN, 3 kN, 5 kN, and 10 kN, were analyzed under identical geometry, material properties, contact settings, and boundary conditions. Contact pressure and sliding distance were selected as the main evaluation indices. The quantitative values used for comparison were extracted from the maximum values in the corresponding post-processing contour plots rather than from an independent analytical estimate. The maximum contact pressure increased from 21.902 MPa to 219.9 MPa as the preload increased from 1 kN to 10 kN, showing an approximately linear growth trend. The maximum sliding distance increased from 0.01584 mm to 0.1582 mm, with a slightly lower amplification ratio than the contact pressure. The results indicate that the preload mainly strengthened the annular compression zone around the bolt hole, while the sliding response represented localized tangential compatibility deformation in the high-pressure contact region. This study provides a baseline numerical reference for understanding the initial assembly-state contact behavior of wind-turbine flange bolted connections.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers