Journal of Physics: Conference Series

COMSOL electric-field simulation and parameter optimization of a high-voltage pulse drill-bit structure

Xinyu Liu, Hongda Li, Yingshuo Liang, Long Che, Chaoming Wang

Computational

Key points

From the paper's conclusion
  • The preferred structure therefore balances rock energization and insulation margin and provides a basis for high-voltage pulse drill-bit design.

Abstract

The drill-bit electrode structure controls energy transfer and insulation safety in high-voltage pulse rock breaking. A COMSOL Multiphysics electrostatic model coupling electrodes, insulating liquid, granite, and a polytetrafluoroethylene (PTFE) insulating wall was established. Rock-domain and liquid-domain peak fields, together with sectional fields at different rock depths, were used to evaluate the basic configuration, number of negative-electrode legs, and insulating-wall thickness. The single-positive surrounding configuration provided the best deep-field retention and lowest liquid-breakdown risk. With six negative-electrode legs and a 1.6 mm PTFE wall, the rock-domain maximum field increased by 57.6%, from 52.997 to 83.512 kV/mm, while the liquid-domain maximum field decreased by 65.9%, from 60.592 to 20.683 kV/mm; the field at 10 mm depth also increased. The preferred structure therefore balances rock energization and insulation margin and provides a basis for high-voltage pulse drill-bit design.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers