Measurement error detection of electric vehicle charging pile operation under multi-segment charging data fusion
Xuliang Zhao, Jiguang Xue, Jun Wang, Gang Liu, Xiaoqi Zhang, Sitong Dong, Yiming Wang
Key points
From the paper's conclusion- A formula for estimating the relative error of a single charge without requiring on-site truth values is derived, and a time-period dynamic correction factor is introduced to improve estimation stability under low-charge conditions, thus achieving metering error detection for electric vehicle charging pile operation.
Abstract
To address the large error ratio between normal and peak periods in the operation of electric vehicle charging piles, a metering error detection method based on the fusion of multi-period charging data is proposed. A charging pile operation model incorporating fixed bias error, gain error, and time-varying interference terms is constructed, establishing the mathematical relationship between instantaneous power and cumulative charge. A confidence-weighted least-squares fusion framework is designed to calculate dynamic weights based on residual variance across time periods and employs a two-stage fusion strategy to separate global error parameters from time-dependent interference. A formula for estimating the relative error of a single charge without requiring on-site truth values is derived, and a time-period dynamic correction factor is introduced to improve estimation stability under low-charge conditions, thus achieving metering error detection for electric vehicle charging pile operation. Experimental results show that, in terms of cross-period error consistency, the designed method maintains a stable error ratio between normal and peak periods between 0.97 and 1.02, and a stable ratio between valley periods between 0.98 and 1.01, with a maximum deviation of only 0.03. On the 8 samples of #P01 charging pile, the design method estimated a maximum relative error of only 0.03% and an average absolute error of 0.02%, while Method A had a maximum error of 0.83% and Method B had an error of 1.0%. In the overall testing of 12 charging piles, the design method correctly detected all 5 abnormal piles with no missed or false alarms, achieving an accuracy of 100%; Method A and Method B had an accuracy of only 83.3%, and Method C had an accuracy of 91.7%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Parameter Fault Prediction in Electric Vehicle Charging Using a CNN-BiGRU Hybrid Deep Learning Model with Sliding Window Residual AnalysisEngineering Research Express · 2026
- Load probabilistic forecasting for electric vehicle charging station cluster: Adaptive multivariate spatiotemporal graph fusion technologyInternational Journal of Electrical Power & Energy Systems · 2025
- Electric vehicles charging stations load forecasting based on hybrid XGBoost-BiLSTM modelScientific Reports · 2026
- Learned Control Variates for Rare Grid-Outage Estimation at Electric Vehicle Charging StationsarXiv · 2026
- A Hierarchical Charging Station Identification Method Integrating Charging-Order Behaviour Mining and Deep Multi-View ClusteringWorld Electric Vehicle Journal · 2026
- A Hybrid Anomaly Detection Method for Electric Vehicle Identification from Smart Meter RecordingsarXiv · 2026