Confinement property in the JT-60SA first operation phase
Yoshiaki Ohtani, Maiko Yoshida, Tomohide Nakano, Ryuichi Sano, Tatsuya Yokoyama, Takuma Wakatsuki, Shizuo Inoue, Hajime Urano
Key points
From the paper's conclusion- Because local measurements of ion temperature T i , electron density and effective charge are not available in the first operation phase and the number of discharges and their parameter range are limited, the present results should not be considered definitive.
Abstract
In JT-60SA, the global energy confinement time τ E has been evaluated to be 0.1-0.2 s for 1 MA hydrogen discharges and compared with the ITERL-96P(th) scaling. Because local measurements of ion temperature T i , electron density and effective charge are not available in the first operation phase and the number of discharges and their parameter range are limited, the present results should not be considered definitive. As heating power increased, τ E tends to shorten in the same trend as the scaling. τ E is shorter than the scaling but approaches the scaling with increasing density. For 0.4-0.6 MW ohmic heating plasmas, τ E increases with increasing collisionality and saturates. For 0.6-0.8 MW ohmic heating and electron cyclotron resonance heating (ECH) plasmas, τ E continues to increase up to higher collisionality and reaches the scaling. The turbulence simulations with the trapped gyroLandau-fluid model assuming a linear T i profile show that the dominant turbulence mode is trapped electron modes. The linear growth rate decreases with increasing collisionality and saturates at a low level in the 0.4-0.6 MW ohmic heating plasma, suggesting the transition from the linear ohmic confinement regime to the saturated ohmic confinement regime. For 0.6-0.8 MW ohmic heating and ECH plasmas, the saturation occurs at higher collisionality, indicating that the linear confinement regime extends to higher collisionality. The global particle confinement time excluding recycling contributions, τ p , has also been evaluated to be 0.301±0.015 s, approximately twice τ E , from the frequency responses in a density feedback control experiment. From τ p and the effective particle confinement time including recycling τ p * , a recycling coefficient is obtained as 0.865±0.013. The sub-unity recycling coefficient indicates that wall recycling is insufficient to maintain plasma density, consistent with hydrogen retention due to the first hydrogen discharge with continuous gas injection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Global gyro-kinetic ion temperature gradient and trapped electron mode turbulence modelling in X -point geometry in negative and positive triangularityPlasma Physics and Controlled Fusion · 2026
- Prediction of the tungsten behavior in a high power high current JT-60SA H-mode plasmaPlasma Physics and Controlled Fusion · 2026
- Integrated simulation and instability analysis of drift wave turbulence for the hot ion mode on HL-3 tokamakNuclear Fusion · 2026
- Validation of first-principles turbulence simulation in diverted negative triangularity plasmas on DIII-DPhysics of Plasmas · 2026
- First global gyrokinetic profile predictions of ITER burning plasmaNuclear Fusion · 2026
- Electrostatic full-f gyrokinetic simulation of microturbulence in tokamak using canonical Maxwellian distributionPhysics of Plasmas · 2026