Neutronics characterisation of the radiation environment for the qualification of magnetic sensors on DEMO
Raul Luís, Antonio Quercia
Key points
From the paper's conclusion- Overall, the results presented in this paper establish the boundaries of the radiation environment that must be sustained by the magnetic diagnostic front-end components over the plant lifetime, and provide the quantitative neutronics basis for the irradiation testing and qualification program required to advance the Technology Readiness Level (TRL) of the DEMO magnetic sensors from the proof-of-c
Abstract
Magnetic sensors are a primary diagnostic tool for plasma control on DEMO, required to measure the local distribution of magnetic fields at multiple positions. As these sensors must be located between the Breeding Blanket (BB) and the Vacuum Vessel (VV), they will be exposed to a harsh radiation environment, with neutron fluences expected to exceed those of ITER by up to an order of magnitude. This paper presents a comprehensive assessment of the radiation environment at the expected locations of magnetic sensors in DEMO, for both the Helium-Cooled Pebble Bed (HCPB) and Water-Cooled Lithium Lead (WCLL) BB configurations. MCNP simulations were performed using heterogeneous reference models of both blankets. Neutron and gamma fluxes, nuclear heat loads, dose rates and displacements per atom were estimated at 60 in-vessel and 60 ex-vessel positions, distributed poloidally around the plasma. The HCPB configuration produces a maximum in-vessel neutron flux of 3.6×10 13 n cm -2 s -1 at the equatorial inboard positions, a factor 18 higher than the WCLL value at the same location. The WCLL maximum in-vessel neutron flux is 8.6×10 12 n cm -2 s -1 , found below the divertor, where the shielding is less effective. The impact of the Magnetic Strip (MS) – a modular structure proposed to integrate the sensors while ensuring compatibility with Remote Maintenance (RM) – was also assessed, through a parametric study in which the radial thickness of the MS envelope was varied between 5 and 11 cm. Overall, the results presented in this paper establish the boundaries of the radiation environment that must be sustained by the magnetic diagnostic front-end components over the plant lifetime, and provide the quantitative neutronics basis for the irradiation testing and qualification program required to advance the Technology Readiness Level (TRL) of the DEMO magnetic sensors from the proof-of-concept stage to full validation in a fusion-relevant environment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hybrid magnetic diagnostics on DEMO: general concept and integration studiesNuclear Fusion · 2026
- Neutral gas pressure gauges in magnetic confinement fusion: From ASDEX Upgrade/W7-X to ITER/SPARC and beyond (invited).The Review of scientific instruments · 2026
- Conceptual design of high-dynamic-range spectroscopy for neutral flux measurements in SPARC.The Review of scientific instruments · 2026
- Energy-resolved neutral profile measurements on MAST upgrade using passive Balmer-alpha spectroscopy.The Review of scientific instruments · 2026
- First assessment of neutral gas transport in the EU DEMO low aspect ratio divertorPlasma Physics and Controlled Fusion · 2026
- Design and integration studies of a DCLL breeding blanket for a stellarator reactor based on the CIEMAT-QI4X configurationPlasma Physics and Controlled Fusion · 2026