  • Abstract We report observations from the first experimental tests of a dedicated runaway electron mitigation coil (REMC) installed inside a tokamak’s vacuum vessel and driven by the disruption loop voltage.

Abstract

Abstract We report observations from the first experimental tests of a dedicated runaway electron mitigation coil (REMC) installed inside a tokamak’s vacuum vessel and driven by the disruption loop voltage. An REMC may provide a ‘fail-safe’ avoidance of high-energy runaway electrons avalanching during disruptions. This REMC operates in the HBT-EP tokamak, with a coil geometry similar to the one planned for the SPARC tokamak and future devices. About 10% of the pre-disruption plasma current is present in the REMC by the middle of the current quench, reaching ∼14% at the peak of the REMC current. Coupling directly from I p is reduced to ∼8% and ∼10% respectively when removing contributions from ramping equilibrium coils. Measured coupling is well-modeled with the ThinCurr 3D thin-wall electromagnetic code that self-consistently computes eddy currents in the tokamak’s conducting structures. When the REMC is activated, we measure asymmetric variations in halo current that are consistent with the large n = 1 magnetic perturbation. Confinement of runaway electrons is studied using hard x-ray emission, though confinement results are inconclusive for this first campaign.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers