An implantable wireless battery-free spatially selective vagus nerve stimulator.
Edvards Rutkovskis, Enrico Ravagli, Henry T Lancashire, Ahmad Shah Idil, Nicole Thompson, Justin D Perkins, Ronald Challita, Joseph Hadaya,
Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building - Gower Street - London, London, WC1E 6BT, United Kingdom of Great Britain and Northern Ireland. · Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London, WC1E 6BT, United Kingdom of Great Britain and Northern Ireland.
Key points
From the paper's conclusion- This work demonstrates the feasibility of wireless battery-free sVNS for cardiac applications using a temporary implantable device. Geometrically selective stimulation has the potential to improve therapeutic efficacy while reducing stimulation-related side effects, and may facilitate future therapies for heart failure and other autonomic disorders.
Abstract
OBJECTIVE: Vagus nerve stimulation (VNS) is an established clinical therapy for drug-resistant epilepsy and other inflammatory conditions. However, off-target stimulation can produce unwanted side effects that limit therapeutic stimulation and hinder the development of new neuromodulation therapies. Selective VNS (sVNS) offers a strategy to reduce off-target organ activation; however, this approach is not available in humans, and no implantable or portable devices exist to trial sVNS in the clinical setup. This work aimed to design, manufacture, and validate an implantable wireless, battery-free stimulator with a selectively addressable output stage for targeted current delivery to specific regions of the human vagus nerve (VN). APPROACH: We developed a near-field communication-controlled, wirelessly powered, battery-free, temporary implantable multichannel stimulation device, compatible with a 15-channel sVNS cuff electrode (14 selective electrode pairs and one circumferential whole-nerve channel). The device was encapsulated for short-term implantation and evaluated through benchtop characterisation, accelerated ageing, and validation in an acute porcine and a pilot human study. MAIN RESULT: The sVNS device was evaluated in a porcine (n = 4) trial and a first-in-human pilot study (n = 1). Selective bradycardia of 23.28 ± 12.91% was observed in pigs and 7.5% in the human participant. In the human, a clear separation of bradycardic and tachycardic effects was observed, with additional selectivity in laryngeal activity. Cardiac and laryngeal responses were separated by 231° around the circumference of the nerve. SIGNIFICANCE: This work demonstrates the feasibility of wireless battery-free sVNS for cardiac applications using a temporary implantable device. Geometrically selective stimulation has the potential to improve therapeutic efficacy while reducing stimulation-related side effects, and may facilitate future therapies for heart failure and other autonomic disorders.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiopulmonary effects of vagus nerve stimulation in mice.eNeuro · 2026
- A Review of Vagus Nerve Stimulation for Disease: Comprehensive Theory and Evidence for Mechanisms of ActionComprehensive physiology · 2026
- Transcutaneous Auricular Vagus Nerve Stimulation in a Pacemaker-Dependent Child with Syndromic Drug-Resistant Epilepsy: A Case Report with Prospective 9-Month Follow-Up.Case reports in neurology · 2026
- Vagus Nerve Stimulation for Sleep Disorders: Emerging Evidence and Future Directions.Nature and science of sleep · 2026
- Site-specific stimulation imperative: Lessons from a failed auricular-cervical transcutaneous vagus nerve stimulation comparison using closely matched parametersBrain stimulation · 2025
- NORA: Neuro-headstage for Online Recording and Actuation in Freely Behaving Animal ModelsarXiv · 2026