CORSICA: Reproducible suppression of cochlear implant artifacts in EEG evoked by continuous speech
C. Jehn, Clara Stiller, Niki Vavatzanidis, Tobias Reichenbach
Friedrich-Alexander-Universität Erlangen-Nürnberg · University Hospital Carl Gustav Carus
Key points
From the paper's conclusion- Our findings demonstrate that objective CI artifact suppres-
sion in speech-evoked EEG data is feasible on the basis of the IC's temporal response
patterns.
Abstract
Abstract Objective Electroencephalography (EEG) is a key tool for studying auditory processing in cochlear implant (CI) users. In particular, EEG recordings obtained during continuous speech are becoming increasingly important for assessing speech and language processing in CI users, and may be utilized for neurofeedback. However, CIs also induce strong stimulation artifacts that are time-locked to the stimulus and mask the neural responses that have smaller magnitudes. Existing artifact reduction methods are typically based on event-related potentials (ERPs) or require manual component selection, making them unsuitable for naturalistic listening conditions or large datasets. Approach We develop CORSICA (CORrelation-baSed ICA artifact rejection), a reproducible, parameter-efficient method for CI artifact reduction in EEG responses to continuous speech. CORSICA operates on independent components (ICs) obtained through Infomax ICA and requires no manual component labelling, with performance governed by a single tunable threshold. It exploits the observation that CI artifacts temporally follow the audio signal without delay, whereas neural responses have an inherent lag due to auditory pathway latencies. For each IC, CORSICA computes the cross-correlation with the speech stimulus. Artifacts are identified by a high signal-to-noise ratio (SNR) of the correlation peak near zero lag, and the component is rejected if this SNR exceeds a threshold. To benchmark CORSICA, we evaluate two alternatives: a TRF-based SNR method, in which temporal response functions are fitted to each IC and artifact-driven peaks near zero lag are used for rejection, and a variant replacing ICA with second-order blind identification (SOBI) as the source separation step. Main results CORSICA effectively suppressed CI artifacts while preserving neural activity, enabling recovery of physiologically plausible TRFs with only 2% of ICs rejected. Both benchmark methods confirmed the validity of the SNR-based rejection framework, but CORSICA outperformed the TRF-based alternative in artifact suppression quality. Replacing ICA with SOBI as the source separation step required more ICs to be rejected, further supporting ICA as the preferred backbone for CORSICA. Significance CORSICA provides a fully objective, label-free approach to identifying CI artifacts in speech-evoked EEG data, with no manual intervention required. By centering artifact rejection on a single interpretable threshold, it offers a reproducible preprocessing standard for future EEG studies on speech processing in CI users. Conclusion Our findings demonstrate that objective CI artifact suppression in speech-evoked EEG data is feasible on the basis of the IC’s temporal response patterns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimisation of and mechanisms behind neural distortion responses obtained with cochlear-implant stimulation by interleaved pulse trainsmedRxiv · 2026
- Real-time noise cancellation for EEG monitoring and brain-computer interfacesbioRxiv · 2026
- Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation StudyarXiv · 2026
- Artefact-free EEG during temporal interference stimulation reveals phase-specific modulation of the human visual cortexbioRxiv · 2026
- Association between ECAP signal artifacts and electrical components from a cochlear implant impedance model.Zeitschrift fur medizinische Physik · 2026
- ICA-S3M: switching state-space model guided automatic EEG artifact removal from independent componentsFrontiers in Neuroscience · 2026