Superconductor Science and Technology

Guaranteed error bounds for AC loss calculations in type-II superconductors: a certified framework from the Bean model to the E-J power law via a space-time convex-duality estimate

Hakeim Talleb

Key points

From the paper's conclusion
  • The same estimate certifies the Bean model on meshes not aligned with the drive, with brackets shrinking from 46% to 1.4% under refinement.

Abstract

Numerical AC loss calculations are validated by cross-comparison of codes, analytical limits and measurements, without mathematically guaranteed error bounds. This paper constructs certified two-sided bounds on the loss per cycle for a one-dimensional slab in a parallel applied field, the verification setting of Bean's analysis, from the critical-state model to the isothermal E-J power law with a field-independent critical current density. For the Bean model with drive steps aligned to the mesh, an exact-in-time catch-up scheme with duality-gap certificates encloses the loss within brackets of relative width below 1.1% that contain Bean's analytical values. For the power law, the per-step primal-dual gap is an exact identity whose strong-convexity modulus, carried by the mass term, is independent of n: certificate effectivities stay between 4.3 and 8.9 for n = 5 to 80. The main result is a space-time majorant derived from the Brezis-Ekeland-Nayroles principle: for any trajectory with exact boundary and initial data and any electric field reconstructed exactly from Faraday's law, the integrated Fenchel-Young constitutive residual bounds the squared error at every time. Combined with a comparison lemma for the boundary data, it certifies the loss per cycle of the slab driven by the exact 50 Hz sinusoid, spatial, temporal and quantity-of-interest errors included, with relative bracket widths of 16% to 20% for n = 5 to 80; the bound on the loss overestimates the true loss error by a factor of 51 to 315, a conservatism whose sources are quantified. The same estimate certifies the Bean model on meshes not aligned with the drive, with brackets shrinking from 46% to 1.4% under refinement. The assumptions behind the guarantees, convexity in the current density at fixed field and isothermal operation, and the developments required for thin strips and coated conductors in perpendicular field are stated explicitly.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers