Mechanism and mitigation of anomalous V-I characteristics in Ic measurements of fully filamentised REBCO tapes
Xiaohui Lin, Junhao Zhang, Sikan Chen, Jicheng Wu, Ye Huang, Chao Zhang, Yanan Cheng, Junjie Sun,
Key points
From the paper's conclusion- The results establish a measurement framework for multifilamentary REBCO tapes and illustrate a general metrological principle: when a superconducting layer is subdivided into elements connected by finite inter-element resistance, strategies that explicitly account for transverse current paths must replace the quasi-equipotential assumption of standard four-probe protocols.
Abstract
Critical-current measurements of fully filamentised REBCO coated conductors using the standard four-probe method frequently produce anomalous, poorly reproducible V-I characteristics. These include premature resistive signals and step-like voltage transitions that preclude reliable determination of Ic and the n-value. By combining transport experiments with a nonlinear equivalent circuit model, we show that these anomalies originate from finite inter-filament resistance. The resistance disrupts the quasi-equipotential condition across the tape width, driving non-uniform current sharing among filaments in a pattern governed by the arrangement of current and voltage leads. On this basis, we develop two measurement strategies compatible with industrial reel-to-reel processing, neither of which requires the unfilamentised end margins used in laboratory practice. The Controlled Sequential Transition (CST) method induces a deterministic filament transition sequence, generating step-rich V-I curves from which filament-resolved Ic values are extracted through model-driven regression with approximately 5% consistency under reversal of the current injection direction. The Pre-Distributed Current (PDC) method suppresses redistribution by apportioning the transport current according to the expected Ic of each filament, yielding smooth, conventional V-I curves. Across all ten nominally identical samples at 77 K in self-field, the PDC method recovers Ic within approximately ±1.5% of the reference with voltage taps placeable on any filament. Direct readout from the CST method systematically overestimates the n-value, by +70% to +246% across the ten samples (mean +120%) — a bias that the analytical model captures semi-quantitatively. We recommend the PDC method for critical-current calibration at the tape ends and the CST method for filament-level defect diagnostics during conductor development. The results establish a measurement framework for multifilamentary REBCO tapes and illustrate a general metrological principle: when a superconducting layer is subdivided into elements connected by finite inter-element resistance, strategies that explicitly account for transverse current paths must replace the quasi-equipotential assumption of standard four-probe protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Critical current distribution prediction in REBCO coated conductors via magnetization field and electromagnetic inversionSuperconductivity · 2025
- DC performance test of twisted stacked slotted-core CICC prototype under 80 kA current and 10.85 T background fieldSuperconductor Science and Technology · 2026
- Design and characterization of a low-resistance joint for TSTC-CICC conductorsSuperconductor Science and Technology · 2026
- Numerical modelling of current non-uniformity in braided stacks of tapesSuperconductor Science and Technology · 2026
- Temperature, magnetic field, and field angular dependence of critical current of REBCO intermediate grown superconducting jointSuperconductor Science and Technology · 2025
- Critical current enhancement in REBCO coated conductors: Pinning dimensionality, operating windows, and mixed-defect architecturesSuperconductor Science and Technology · 2026