Smart Materials and Structures

Influence of reinforcement architecture on force and deformation in multilayer silicone dielectric elastomer actuators

Xiaohan Han, Markus Koenigsdorff, Amine Benouhiba, Yoan Civet, Yves Perriard

Key points

From the paper's conclusion
  • We compared multilayer silicone actuators without reinforcement (ISO) with actuators reinforced by discrete, evenly spaced polyethylene terephthalate (PET) strips or a continuous carbon fiber (CF) elastomer composite.

Abstract

Reinforcement can increase the electroactive force of dielectric elastomer actuators (DEAs), but it also introduces additional mechanical stiffness. Both effects should therefore be considered when evaluating reinforcement architectures for deformation under load. We compared multilayer silicone actuators without reinforcement (ISO) with actuators reinforced by discrete, evenly spaced polyethylene terephthalate (PET) strips or a continuous carbon fiber (CF) elastomer composite. Nine actuators, three per architecture, underwent a displacement-controlled cyclic test, a fixed-stretch test, and a fixed-load test. From the force–stretch curves, we calculated passive slope, hysteresis loss, electroactive force, and cyclic strain at prescribed loads. The PET group had the largest mean passive slope and electroactive force, while the PET and CF groups produced similar cyclic strains. The force-to-passive-slope ratio was more strongly related to cyclic strain than electroactive force alone (r = 0.959). Leave-one-specimen-out cross-validation gave an RMSE of 0.141 percentage points. These results show that reinforcement design must balance electroactive force against passive resistance when motion under load is the target. Fixed-stretch electroactive force agreed closely with the cyclic value, with an RMSE of 4.4 mN. At 3 kV, cyclic strain exceeded fixed-load strain by 0.21 percentage points on average, with a relative RMSE of 8.5%. This cross-protocol discrepancy was also reflected in the relative performance of the architectures: the CF group had the largest mean fixed-load strain at all three loads. With acceptable agreement across testing protocols, the workflow provides a basis for characterizing and comparing reinforcement architectures and informing their selection for deformation under load.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of reinforcement architecture on force and deformation in multilayer silicone dielectric elastomer actuators — Science Skim