Optimizing power transfer in magnetoelectric transducers for wireless powering of biomedical implants
Elise Maxine Wendlandt, Soren Lieu Neumann, Cuong Phu Le, Binh Duc Truong
Key points
From the paper's conclusion- The results show that the optimal power is achieved uniquely at mechanical resonance and increases monotonically with an effective figure of merit, yielding a physically attainable maximum power strictly below the theoretical bound and a finite operating bandwidth.
Abstract
This work studies the operating principles and performance limits of magnetoelectric transducers, which are promising compact receiver alternatives for wireless powering of biomedical implantable devices. We develop an analytical framework to investigate the maximum power that can be transferred to an electrical load. Although an electrically lossless model is widely used to explore the magnetoelectric transducer capability, we find that in this idealization, allowing a complex-valued load impedance enables the delivered power to attain the physical bound at an arbitrary operating frequency and with any electromechanical coupling strength. This behavior may not be feasible in practice. To reflect a more realistic potential of a magnetoelectric wireless power transfer system, the inevitable electrical losses are taken into account. We derive closed-form expressions for the maximum output power under a general complex load, in both series and parallel configurations, and determine the corresponding optimal conditions. The results show that the optimal power is achieved uniquely at mechanical resonance and increases monotonically with an effective figure of merit, yielding a physically attainable maximum power strictly below the theoretical bound and a finite operating bandwidth. Motivated by implant-size limitations, we formulate a power optimization subject to volume constraints. We establish an analytical condition for the optimal thickness ratio, defined as the ratio between the piezoelectric thickness and the total thickness of the composite. The conventional magnetoelectric voltage coefficient is also considered. It is shown that there exist scenarios in which reducing the thickness ratio can maximize both the power delivered and the voltage coefficient, unifying an optimal setting for wireless power transfer and sensing. These findings provide a comprehensive understanding and a general framework for realizing an efficient magnetoelectric-based system for biomedical implants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetoelectric Wireless Power Transfer Receivers for Sub-Millimeter Scale Implantable BioelectronicsarXiv · 2026
- Omnidirectional Magnetoelectric Wireless Power Transfer for Implantable Intracranial Pressure Monitoring.IEEE transactions on biomedical circuits and systems · 2026
- Implantable Inductive Power Transfer: A Review of System Design, Safety, and ReliabilityElectronics · 2026
- Optimised Design and Characterisation of an Implantable Flexible Wireless Power-Transfer System Based on an LCC-S Topology.Sensors (Basel, Switzerland) · 2026
- Wireless Power Transfer Modalities for Implantable Bioelectronics: Electromagnetic, Acoustic, and Magneto‐Dynamic PerspectivesAdvanced Materials Technologies · 2025
- On‐Chip Ultra Small 900‐MHz Wireless Powering Transfer for Smart Biomedical DevicesInternational Journal of Circuit Theory and Applications · 2026