Optical fiber sensing under high strain gradients: a multi-technology benchmark against finite element predictions
Damiano Gianotti, Sylvain Magne, François Di Paola, Benjamin Sapaly, Yves Van Ingelgem, Iris De Graeve
Key points
From the paper's conclusion- Three centimetre-scale sensing technologies are
benchmarked against finite element method (FEM) predictions: fiber Bragg gratings
(FBGs) in wavelength-division multiplexing (WDM), continuous fiber gratings (CFGs) in
frequency-modulated continuous-wave (FMCW), and optical frequency-domain
reflectometry (OFDR) under high strain gradients (HSGs) reaching around 200 µε mm−1.
HSGs a
Abstract
Distributed and quasi-distributed optical fiber sensors (OFS) are deployed for structural health monitoring (SHM) of structures, yet their accuracy near sub-centimetre stress concentration areas remains uncertain. Three centimetre-scale sensing technologies are benchmarked against finite element method (FEM) predictions: fiber Bragg gratings (FBGs) in wavelength-division multiplexing (WDM), continuous fiber gratings (CFGs) in frequency-modulated continuous-wave (FMCW), and optical frequency-domain reflectometry (OFDR) under high strain gradients (HSGs) reaching around 200 µε mm−1. HSGs are generated in a 2 mm thick aluminium plate (80 × 765 mm2) with three holes (diameters Φ = 30 mm, 40 mm and 50 mm) loaded up to 2200 N by steps of 200 N. Gage-length averaging is the dominant error mechanism at the 40 mm and 30 mm holes when compared with the FEM structural benchmark: an 8 mm type-I FBG underestimates the FEM peak by 24 % and 30 %, respectively, while a 3 mm type-III FBG reduces this to around 10 % to 15 %. At the 50 mm hole, FBG type-III remains below FEM by about 12 % (1941 µε vs 2209 µε at 2000 N); at 1000 N, FEM, OFDR, and FMCW peaks are 1113.4 µε, 1332.25 µε (+20 %), and 555.4 µε (-50 %), respectively. OFDR requires moving-reference processing above 1600 N to prevent correlation breakdown. The relative accuracy of the 2 mm and 9 mm CFG-FMCW configurations varies with hole size and depends on gage overlap fraction; FMCW damping or spectral distortion occurs in high-gradient regions and is consistent with gradient-dependent spectral distortion, potentially involving chirp and proprietary peak-detection processing. These results provide guidance for sensor selection, gage-length specification, and signal-processing choices in SHM deployments where damage-induced strain concentrations are expected. Mitigation perspectives include transfer-function-informed correction (regularized deconvolution) and hybrid OFDR–FBG data fusion to preserve peak fidelity while retaining spatial coverage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intelligent Distributed Optical Fiber Sensing in Transportation Infrastructures: Research Progress, Applications, and ChallengesAdvanced Photonics Research · 2026
- Comparative Analysis and Optimization of Sensitivity Enhancement Methods for Fiber-Optic Strain Sensors in Structural MonitoringFibers · 2026
- Fiber-Optic Sensor Technologies for Concrete Structural Health Monitoring: Measurement Chains, Interrogation Approaches, and Research TrendsPhotonics · 2026
- Fiber-Optic Sensor-Based Structural Health Monitoring with Machine Learning: A Task-Oriented and Cross-Domain ReviewSensors · 2026
- A Review of Multiparameter Fiber-Optic Distributed Sensing Techniques for Simultaneous Measurement of Temperature, Strain, and Environmental EffectsSensors · 2025
- Bayesian tendon breakage localization under model uncertainty using distributed fiber optic sensorsData-Centric Engineering · 2026