Smart Materials and Structures

Study on the actuation performance of ionic liquidbased square-columnar IPMC under low temperature

Qingsong He, Yuze Ye, Weiming Xu, Ji Lu, Siyuan Liu, Hu Hou, Daiwei Cun, Qiyun Zhong,

Key points

From the paper's conclusion
  • This study investigates the effects of thickness (0.6, 0.8, and 1.0 mm) and temperature (-20 ℃ to 20 ℃) on the electrochemical and electro-mechanical properties of single-pair electrode IL-IPMCs (SE-IL-IPMCs).

Abstract

Ionic polymer-metal composites doped with ionic liquids (IL-IPMCs) demonstrate immense potential for applications in the field of soft robotics. However, their actuation behavior at low temperatures and their complex three-dimensional (3D) motion remain largely unexplored. This study investigates the effects of thickness (0.6, 0.8, and 1.0 mm) and temperature (-20 ℃ to 20 ℃) on the electrochemical and electro-mechanical properties of single-pair electrode IL-IPMCs (SE-IL-IPMCs). Larger thickness and lower temperature results in smaller current, output angle, and specific capacitance-due to the restricted mobility of internal ions. Both the SE-IL-IPMC-0.6 and SE-IL-IPMC-0.8 deliver greater DC output angle, specific capacitance and operating currents, alongside more favorable cyclic voltammetry profiles. After more than 1000 cycles, the displacement attenuation rate does not exceed 11 %. SE-IL-IPMC-0.8 and SE-IL-IPMC-1.0 demonstrate better AC cycling stability than SE-IL-IPMC-0.6. Consequently, using the SE-IL-IPMC-0.8 as a baseline, we successfully designed and fabricated a novel two-pair electrode square-columnar IL-IPMC (TES-IL-IPMC-0.8). TES-IL-IPMC-0.8 exhibits anisotropy with a higher specific capacitance along the Y-axis, which is very close to that of SE-IL-IPMC-0.8. Furthermore, broad-temperature evaluations (-20 ℃ to 20 ℃) indicate that the relative variation of the X-axis and Y-axis bending capabilities of the TES-IL-IPMC-0.8 with respect to the performance of the SE-IL-IPMC-0.8 is less than 17%. It demonstrates excellent cycling stability, retaining 91.87% and 90.65% of its initial displacement amplitudes in the X and Y axes, respectively, after 1000 AC cycles. By independently applying voltages across two orthogonal directions, a single TES-IL-IPMC-0.8 unit can effectively execute continuous circular scans and trace precise right-angled triangular trajectories. This work validates the immense engineering potential of the developed actuators within the realm of advanced soft robotics, establishing a viable paradigm for micromanipulators.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Study on the actuation performance of ionic liquidbased square-columnar IPMC under low temperature — Science Skim