Predictive full radius integrated modelling of plasma current impact on WEST L-mode confinement
Enzo Vergnaud, Clarisse Bourdelle, Yann Camenen, Theo Fonghetti, Pierre Manas, Jean-Francois Artaud, Francis J Casson, Nathan Cummings,
Key points
From the paper's conclusion- Finally, a virtual IP scan applied to one pulse between 0.2 and 0.8 MA shows a dependence of the confinement time on plasma current with an exponent of 0.42, much weaker than the ITER-L96 one (αIP = 0.96).
Abstract
Integrated modelling simulations with the High Fidelity Pulse Simulator (HFPS) are carried out to address the strong correlation of the plasma current on the energy confinement time observed experimentally in tokamak plasmas and reported in scaling laws. The simulations are performed for eight WEST electron-heated L-mode plasmas, with Lower Hybrid current drive, covering a range of plasma current from 0.26 MA to 0.5 MA at comparable injected power and line-average density. The input parameters for the HFPS simulations are the engineering parameters, as for scaling laws, together with the separatrix quantities and the radiative fraction. The eight full-radius simulations performed with the physics based quasilinear code TGLFsat2 and including tungsten and nitrogen impurities reproduce the experimental energy content within 8%, better than the 24% obtained from the ITERL96 scaling law. The predicted profiles are compared to experimental measurements using synthetic diagnostics for ECE, interferometry, bolometry and the neutron rate. The agreement improves when heat and particle transport are predicted self-consistently, from 20-40% with heat flux prediction only down to 10-20% when particle transport prediction is included. TGLFsat2 is verified stand-alone against the higher fidelity gyrokinetic code GKW revealing a TEM dominated regime in the core and a transition towards resistive modes closer to the edge. Finally, a virtual IP scan applied to one pulse between 0.2 and 0.8 MA shows a dependence of the confinement time on plasma current with an exponent of 0.42, much weaker than the ITER-L96 one (αIP = 0.96). To go further, an HFPS-based scaling law is derived from a database of 25 simulations spanning the plasma current, the electron density and the power, yielding the same weak αIP. This exponent remains compatible with the experimental data, since constraining the experimental regression to this value increases the RMSE by only 3% (from 12% to 15%).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance Assessment of a GEM-Based SXR Diagnostic System Operating in the WEST Plasma EnvironmentEnergies · 2026
- Ripple-induced fast-ion losses modeling in the WEST tokamakNuclear Fusion · 2026
- WEST advanced wall protection achievements toward long pulse operationNuclear Fusion · 2026
- Simulations of turbulent heat and particle transport in stellarator plasmasarXiv · 2026
- TRANSP-TGLF core predictive modeling of the JET DT baseline scenarioNuclear Fusion · 2026
- Integrated simulation and instability analysis of drift wave turbulence for the hot ion mode on HL-3 tokamakNuclear Fusion · 2026