Plasma Physics and Controlled Fusion

On the timescales of controlled termination of tokamak plasmas

Simon Van Mulders, Olivier Sauter

Computational

Key points

From the paper's conclusion
  • For burning plasmas, ITER baseline simulations show that a termination within 150% of the L-mode τLR can avoid negative edge current density and a large ℓi3 increase for an HL transition 1/3rd into the ramp-down.

Abstract

The RAPTOR code is used to model how the time required for controlled termination of Ohmic plasmas scales from present tokamaks like TCV and JET, to reactor-grade tokamaks like ITER and DEMO. We show that ramping the plasma current Ip down to 20% of the flat-top value over a time Δt ramp−down =τLR=Li/R, with internal inductance Li and resistance R evaluated at flat-top conditions, results in an approximately self-similar peaking of the current density for these four tokamaks, indicating the adequacy of τLR as a relevant timescale for cross-machine comparison, yielding τLR= 0.033s (TCV), 2.87s (JET), 63.2s (ITER) and 166.9s (DEMO). Note that τLR is easy to evaluate, both in systems codes and on a real-time control system. For the simulated ramp-downs with Δt ramp−down =τLR, the end-of-ramp-down normalized internal inductance ℓi3 is limited below 2. An Ip ramp-down faster than τLR=Li/R requires a reversal of the boundary loop voltage and leads to the formation of a broad plasma layer carrying current in the direction opposite to the total plasma current, concomitant with ℓi3>2, a central region with low magnetic shear and strongly peaked pressure profiles. Significant reduction of plasma volume and elongation, as foreseen for ITER and DEMO, is shown to counteract the reversal of current density and the ℓi3 increase, while easing vertical stability control, potentially enabling faster Ip ramp-down scenarios. Experimental and theoretical studies should be performed to test the feasibility of such fast termination scenarios, notably with respect to vertical position control, shape control and (resistive) beta limits. An analytical model is proposed to estimate τLR based on 0D engineering parameters. For burning plasmas, ITER baseline simulations show that a termination within 150% of the L-mode τLR can avoid negative edge current density and a large ℓi3 increase for an HL transition 1/3rd into the ramp-down.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

On the timescales of controlled termination of tokamak plasmas — Science Skim