On the timescales of controlled termination of tokamak plasmas
Simon Van Mulders, Olivier Sauter
Key points
From the paper's conclusion- For burning plasmas, ITER baseline simulations show that a termination within 150% of the L-mode τLR can avoid negative edge current density and a large ℓi3 increase for an HL transition 1/3rd into the ramp-down.
Abstract
The RAPTOR code is used to model how the time required for controlled termination of Ohmic plasmas scales from present tokamaks like TCV and JET, to reactor-grade tokamaks like ITER and DEMO. We show that ramping the plasma current Ip down to 20% of the flat-top value over a time Δt ramp−down =τLR=Li/R, with internal inductance Li and resistance R evaluated at flat-top conditions, results in an approximately self-similar peaking of the current density for these four tokamaks, indicating the adequacy of τLR as a relevant timescale for cross-machine comparison, yielding τLR= 0.033s (TCV), 2.87s (JET), 63.2s (ITER) and 166.9s (DEMO). Note that τLR is easy to evaluate, both in systems codes and on a real-time control system. For the simulated ramp-downs with Δt ramp−down =τLR, the end-of-ramp-down normalized internal inductance ℓi3 is limited below 2. An Ip ramp-down faster than τLR=Li/R requires a reversal of the boundary loop voltage and leads to the formation of a broad plasma layer carrying current in the direction opposite to the total plasma current, concomitant with ℓi3>2, a central region with low magnetic shear and strongly peaked pressure profiles. Significant reduction of plasma volume and elongation, as foreseen for ITER and DEMO, is shown to counteract the reversal of current density and the ℓi3 increase, while easing vertical stability control, potentially enabling faster Ip ramp-down scenarios. Experimental and theoretical studies should be performed to test the feasibility of such fast termination scenarios, notably with respect to vertical position control, shape control and (resistive) beta limits. An analytical model is proposed to estimate τLR based on 0D engineering parameters. For burning plasmas, ITER baseline simulations show that a termination within 150% of the L-mode τLR can avoid negative edge current density and a large ℓi3 increase for an HL transition 1/3rd into the ramp-down.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D modelling of runaway electron deconfinement by MHD instabilities in ITER mitigated disruptions: from avalanche to terminationNuclear Fusion · 2026
- Effect of scrape-off losses and current flattening on runaway electron dynamics in ARCarXiv · 2026
- Modeling runaway electron mitigation via passively driven plasma instabilities in a high-current tokamakarXiv · 2026
- Learning plasma dynamics and robust rampdown trajectories with predict-first experiments at TCVNature Communications · 2025
- Progress and innovations in the TCV tokamak research programmeNuclear Fusion · 2026
- The Roadmap for runaway electron-induced plasma facing component damage in tokamaksPlasma Physics and Controlled Fusion · 2025