Measured, not labelled: un-analyzable input versus misclassification in single-lead wearable ECG.
Yunfei Cheng, Peng Deng, Yun Lian, Ruichen Yang, Huibin Sun
Health Technology and Engineering Research Center, SKG Health Technologies Co., Ltd., 23A Floor, Building 3, Zhongke R&D Park, No.009, Gaoxin South 1st Road, High-tech Zone Community, Yuehai street, Nanshan District, Shenzhen, Guangdong, 518063, China.
Key points
From the paper's conclusion- We ask how much deployment error is un-analyzable input rather than misclassification when analyzability is measured with one instrument.

Approach.
Abstract
Wearable single-lead ECG has expanded arrhythmia screening, but many recordings are inconclusive, and each corpus defines that word differently. We ask how much deployment error is un-analyzable input rather than misclassification when analyzability is measured with one instrument. Approach. We evaluate three diagnostic databases in-domain and leave-dataset-out under a strict loss counting windows carrying each corpus's inconclusive label as errors unless deferred. We score analyzability with an unsupervised morphological criterion calibrated against three experts on free-living ECG. Reference unreadability is sparse and imbalanced: only seven of 15 subjects contain an unreadable window and one supplies 88% of all unreadable windows. Thresholded sensitivity and every prevalence or true-share correction are therefore exploratory. Main results. The criterion flags almost all expert-unreadable windows but only subsets of the windows labelled inconclusive by their corpora: an inconclusive rate measures convention as much as signal. At tau_a = 0.50, criterion-positive windows are 8.1%, 56.7% and 69.6% of the strict proxy loss on Holter, handheld and patch. The true-share point intervals lie below 50% on handheld and above it on patch, but joint calibration-and-sampling envelopes span 50% on both and still do at the Youden threshold 0.60. On handheld, the calibration-only envelope is more than twice as wide as the corpus-sampling-only envelope. Gate-versus-confidence ordering changes with the accounting and corpus; no general selective-risk advantage of the gate is established. Significance. Corpus labels, criterion flags and latent expert unreadability must not be conflated. A gate can win by predicting a labelling convention, and this retrospective study validates neither transfer to smartwatch dry electrodes nor improvement in patient outcomes. Measure the inconclusive rate with a stated criterion on the raw signal; do not inherit it from a corpus label.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inter-Lead RRI Agreement Between Lead I and Lead II Across Diagnostic ECG Categories: Pilot Evidence for Wearable HRV MonitoringApplied Sciences · 2026
- Multi-Tier Validation of a Single-Lead Wearable ECG Signal-Processing Pipeline: Clinical Comparison and Algorithmic Benchmarking on Public Expert-Annotated Databases.Sensors (Basel, Switzerland) · 2026
- Accuracy of atrial fibrillation labels in the MIMIC-IV ECG database: implications for artificial intelligence model developmentEuropean Heart Journal · 2026
- Single-Lead ECG Arrhythmia Classification with Machine Learning for IoT HealthcareApplied System Innovation · 2026
- Diagnostic accuracy of multivector smartwatch electrocardiography compared with conventional 12-lead ecgEuropean Heart Journal · 2026
- Interpretable RR Interval-Based ECG Rhythm Abnormality Detection: Cross-Dataset Evaluation, Feature Explainability, and Feature-Level Sensitivity Analysis.Diagnostics (Basel, Switzerland) · 2026